Fluoroscopic Landmark to Optimize the View of the Foramen Ovale Using the Neighboring Structure

Ji-Hee Hong, Se Nyung Huh, Ki Beom Park
{"title":"Fluoroscopic Landmark to Optimize the View of the Foramen Ovale Using the Neighboring Structure","authors":"Ji-Hee Hong, Se Nyung Huh, Ki Beom Park","doi":"10.46308/kmj.2023.00024","DOIUrl":null,"url":null,"abstract":"Radiofrequency thermocoagulation (RFT) via trans-oval approach is effective treat-ment modalities for trigeminal neuralgia. Clear identification of the foramen ovale (FO) is the most important initial step for successful percutaneous procedures. The purpose of this study was to verify whether the medial end of the temporomandibular joint and the distance between the mandibular angle and the occipital inner line can be used as a fluoroscopic landmark to determine the proper angulation of the C-arm. Analysis of previously saved fluoroscopic FO images during RFT was performed. As a fluoroscopic landmark to guide a proper lateral and axial oblique rotation of the C-arm, the position of the medial end of the temporomandibular joint and the vertical distance between the mandibular angle and the occipital inner line were evaluated. When the FO was located at the most central point within the H-fig-ure, the medial end of TMJ was always located within the mandibular notch. The maximum view of the FO was defined when the FO showed maximal short axis to long axis ratio. The FO showed the best view when the vertical distance between the mandibular angle and occipital inner line was 20.04 (5.1) mm. This study demonstrated that the medial end of the temporomandibular joint and the vertical distance between the mandibular angle and occipital inner line as a fluoroscopic landmark for obtaining the optimal view of the FO.","PeriodicalId":166951,"journal":{"name":"Keimyung Medical Journal","volume":"93 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Keimyung Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46308/kmj.2023.00024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Radiofrequency thermocoagulation (RFT) via trans-oval approach is effective treat-ment modalities for trigeminal neuralgia. Clear identification of the foramen ovale (FO) is the most important initial step for successful percutaneous procedures. The purpose of this study was to verify whether the medial end of the temporomandibular joint and the distance between the mandibular angle and the occipital inner line can be used as a fluoroscopic landmark to determine the proper angulation of the C-arm. Analysis of previously saved fluoroscopic FO images during RFT was performed. As a fluoroscopic landmark to guide a proper lateral and axial oblique rotation of the C-arm, the position of the medial end of the temporomandibular joint and the vertical distance between the mandibular angle and the occipital inner line were evaluated. When the FO was located at the most central point within the H-fig-ure, the medial end of TMJ was always located within the mandibular notch. The maximum view of the FO was defined when the FO showed maximal short axis to long axis ratio. The FO showed the best view when the vertical distance between the mandibular angle and occipital inner line was 20.04 (5.1) mm. This study demonstrated that the medial end of the temporomandibular joint and the vertical distance between the mandibular angle and occipital inner line as a fluoroscopic landmark for obtaining the optimal view of the FO.
利用邻近结构优化卵圆孔视野的透视标记
经卵形入路射频热凝术是治疗三叉神经痛的有效方法。清楚地识别卵圆孔(FO)是成功经皮手术的最重要的第一步。本研究的目的是验证颞下颌关节内侧端和下颌角与枕内线之间的距离是否可以作为x线透视标志来确定c臂的合适角度。在RFT期间对先前保存的透视FO图像进行分析。作为引导c臂适当的侧向和轴向斜向旋转的透视标志,我们评估了颞下颌关节内侧端的位置以及下颌角与枕内线之间的垂直距离。当FO位于h形内最中心点时,TMJ内侧端始终位于下颌切迹内。视点的最大视点是视点显示最大的短轴与长轴之比。当下颌骨角与枕内线的垂直距离为20.04 (5.1)mm时,FO显示最佳视角。本研究表明,颞下颌关节内侧端和下颌角与枕内线的垂直距离作为FO最佳视角的透视标志。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信