{"title":"Forced commutation through series voltage injection for reactive power reduction of line commutated HVDC converter terminal","authors":"M. Jafar, M. Molinas","doi":"10.1109/IPEC.2010.5543208","DOIUrl":null,"url":null,"abstract":"This work attempts to explain reactive power consumption in a line commutated HVDC transmission system and suggests a possible solution to reduce it. A series injection strategy has been formulated using voltage-source converters and the effects have been simulated indicating a significant reduction in reactive power consumption by the converter terminal and consequently that supplied by the source. An important outcome is the fact that the suggested set of series injection devices reduces the reactive power consumption of the converter and thus would require smaller size and cost to build. This advantage becomes more significant in case of floating offshore systems which would require lighter support structures.","PeriodicalId":353540,"journal":{"name":"The 2010 International Power Electronics Conference - ECCE ASIA -","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 2010 International Power Electronics Conference - ECCE ASIA -","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2010.5543208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This work attempts to explain reactive power consumption in a line commutated HVDC transmission system and suggests a possible solution to reduce it. A series injection strategy has been formulated using voltage-source converters and the effects have been simulated indicating a significant reduction in reactive power consumption by the converter terminal and consequently that supplied by the source. An important outcome is the fact that the suggested set of series injection devices reduces the reactive power consumption of the converter and thus would require smaller size and cost to build. This advantage becomes more significant in case of floating offshore systems which would require lighter support structures.
通过串联注压强制换相降低线路换向高压直流变流器终端无功功率
这项工作试图解释在线路换向高压直流输电系统的无功功率消耗,并提出了一个可能的解决方案,以减少它。使用电压源变流器制定了一系列注入策略,并对其效果进行了模拟,表明变流器终端的无功功耗显著降低,从而降低了源提供的无功功耗。一个重要的结果是,建议的一系列注入装置减少了转换器的无功功率消耗,因此需要更小的尺寸和成本来建造。在需要较轻支撑结构的浮式海上系统中,这一优势变得更加显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信