Phase comparison protection for distribution networks with high PV penetration

T. Alvin, I. Abidin, H. Hashim, A. A. Z. Zainul Abidin
{"title":"Phase comparison protection for distribution networks with high PV penetration","authors":"T. Alvin, I. Abidin, H. Hashim, A. A. Z. Zainul Abidin","doi":"10.1109/ISGT-ASIA.2014.6873792","DOIUrl":null,"url":null,"abstract":"With the availability and reduced cost of renewable energy sources such as Solar PV, distributed generation (DG) becomes an increasingly common practice in harnessing these energy sources. However, a high level of penetration of the energy sources in the distribution network will cause issues such as reverse power flow and the disruptions to the coordination of existing protection system. This paper looks on how reverse power flow will affect the tripping times of overcurrent relays and its effect on the coordination of the protection system. This paper also investigates on the possibility of using the phase comparison protection method to improve the coordination of the protection system in a high PV penetration environment.","PeriodicalId":444960,"journal":{"name":"2014 IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2014.6873792","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

With the availability and reduced cost of renewable energy sources such as Solar PV, distributed generation (DG) becomes an increasingly common practice in harnessing these energy sources. However, a high level of penetration of the energy sources in the distribution network will cause issues such as reverse power flow and the disruptions to the coordination of existing protection system. This paper looks on how reverse power flow will affect the tripping times of overcurrent relays and its effect on the coordination of the protection system. This paper also investigates on the possibility of using the phase comparison protection method to improve the coordination of the protection system in a high PV penetration environment.
高光伏渗透配电网的相比较保护
随着太阳能光伏等可再生能源的可用性和成本的降低,分布式发电(DG)在利用这些能源方面变得越来越普遍。然而,能源在配电网中的高度渗透会引起反向潮流和破坏现有保护系统的协调等问题。研究了反向潮流对过流继电器脱扣次数的影响及其对保护系统协调性的影响。本文还探讨了在高PV穿深环境下,采用相比较保护方法提高保护系统协调性的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信