{"title":"The closed-loop regulation of blood glucose in diabetics","authors":"E. A. Woodruff, S. Gulaya, R. Northrop","doi":"10.1109/NEBC.1988.19342","DOIUrl":null,"url":null,"abstract":"The development of a system for the closed-loop regulation of blood glucose concentration (BGC) in a Type-1 diabetic when sparse measurements of the blood glucose concentration are available is discussed. A model reference technique to provide an estimate of the BGC is implemented. Whenever, a BGC measurement is not available, the BGC estimate is used in the controller realization. After developing the model reference offline, a computer simulation is realized for closed-loop regulation of blood glucose concentration in a Type-1 diabetic. A recursive parameter-estimation scheme is implemented to update the parameters of the model reference throughout the closed-loop simulation. These parameter estimates can be used to adjust some of the controller parameters to enhance the robustness of the controller.<<ETX>>","PeriodicalId":165980,"journal":{"name":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1988.19342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
The development of a system for the closed-loop regulation of blood glucose concentration (BGC) in a Type-1 diabetic when sparse measurements of the blood glucose concentration are available is discussed. A model reference technique to provide an estimate of the BGC is implemented. Whenever, a BGC measurement is not available, the BGC estimate is used in the controller realization. After developing the model reference offline, a computer simulation is realized for closed-loop regulation of blood glucose concentration in a Type-1 diabetic. A recursive parameter-estimation scheme is implemented to update the parameters of the model reference throughout the closed-loop simulation. These parameter estimates can be used to adjust some of the controller parameters to enhance the robustness of the controller.<>