Replacement of (6) 1000hp DC Drives and Motors with AC

Steve Pittman
{"title":"Replacement of (6) 1000hp DC Drives and Motors with AC","authors":"Steve Pittman","doi":"10.1109/PPIC47846.2021.9620470","DOIUrl":null,"url":null,"abstract":"This paper summarizes a project to replace six aging 1000hp DC (direct current) drives and motors powering dual-shafted fan pumps on a large tissue machine. The drives and motors were failing at an unacceptable rate which created the financial justification for the replacement. Throughout this project, key decisions were made which determined how successful the new installation would be. The most important of these key initial decisions was to replace the failing DC motors with AC (alternating current) motors. Once the project was complete, the realized benefits were stunning and far exceeded the project’s initial simple goal of reliable drives and motors. Additional unexpected benefits included significant energy savings, significant power factor improvement, a much simpler hardware and software infrastructure, and a cooler basement.This paper will discuss:•the driving reason to replace the DC drives.•the justification for replacing the DC motors with AC.•why the motor hp decreased from 1000hp to 700hp.•the decision-making process and project progression.•the benefits and outcomes of the completed project.","PeriodicalId":337924,"journal":{"name":"2021 IEEE IAS Pulp and Paper Industry Conference (PPIC)","volume":"13 8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE IAS Pulp and Paper Industry Conference (PPIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPIC47846.2021.9620470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper summarizes a project to replace six aging 1000hp DC (direct current) drives and motors powering dual-shafted fan pumps on a large tissue machine. The drives and motors were failing at an unacceptable rate which created the financial justification for the replacement. Throughout this project, key decisions were made which determined how successful the new installation would be. The most important of these key initial decisions was to replace the failing DC motors with AC (alternating current) motors. Once the project was complete, the realized benefits were stunning and far exceeded the project’s initial simple goal of reliable drives and motors. Additional unexpected benefits included significant energy savings, significant power factor improvement, a much simpler hardware and software infrastructure, and a cooler basement.This paper will discuss:•the driving reason to replace the DC drives.•the justification for replacing the DC motors with AC.•why the motor hp decreased from 1000hp to 700hp.•the decision-making process and project progression.•the benefits and outcomes of the completed project.
更换(6)1000马力直流驱动器和电机与交流
本文总结了一项更换大型组织机械上6台老化的1000hp直流(直流)驱动和驱动双轴风扇泵的电机的项目。驱动器和马达的失败率令人无法接受,这就为更换提供了经济上的理由。在整个项目中,关键的决策决定了新安装的成功程度。这些关键的初步决定中最重要的是用交流(交流)电机取代故障的直流电机。项目完成后,实现的效益是惊人的,远远超过了项目最初的简单目标,即可靠的驱动器和电机。其他意想不到的好处包括显著的节能、显著的功率因数改善、更简单的硬件和软件基础设施以及更凉爽的地下室。本文将讨论:•取代直流驱动器的驱动原因。•用交流电机替换直流电机的理由•为什么电机的马力从1000马力降到了700马力•决策过程和项目进展。•完成项目的效益和成果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信