{"title":"A Novel 5-pin Fixation for Distal Radius Fractures and Its Functional Assessment","authors":"R. Vipin, N. Rengarajan, M. Manoharan, K. Kesavan","doi":"10.5005/jp-journals-10079-1045","DOIUrl":null,"url":null,"abstract":"Background: Distal radius fractures are an extensively debated topic throughout decades. The treatment options include POP casting, plating, external fixation with or without ligamentotaxis, and K -wiring. This study was conducted to assess the functional outcome of a novel percutaneous 5-pin technique in distal radius fractures. Materials and methods: This is a prospective observational study over 16 months from January 2019 to May 2020. Novel percutaneous 5-pin technique in a sequential configuration following a closed reduction was performed, followed by physiotherapy, and functional outcome was assessed at 6, 12, and 28 weeks following K -wire removal using Cooney’s modification of Green and Obrien scoring and evaluated for functional status, pin loosening, tendon impalement, and nerve injury. Results: All 20 patients were assessed. The mean age of patients was 47.15 years, 10 being females, with road traffic accidents being the major mode of injury. All patients were followed up for 6 months post- K -wire removal and 90% of patients had good to the excellent outcome and 10% of patients had fair to bad outcome with a functional range of supination and pronation movements. All fracture unions were satisfactory and four patients (20%) developed minor complications. None of them developed tendon impalement or nerve injuries. Conclusion: The novel percutaneous 5-pin technique includes two additional ulnoradial wires which provide superior rotational stability and avoid the chance of late collapse and maintain radial height, unlike conventional K -wire techniques. Thus, avoiding the need for more invasive techniques and allows early mobilization of wrist and fingers preventing stiffness, resulting in an excellent outcome.","PeriodicalId":369299,"journal":{"name":"Journal of Orthopedics and Joint Surgery","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopedics and Joint Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10079-1045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Distal radius fractures are an extensively debated topic throughout decades. The treatment options include POP casting, plating, external fixation with or without ligamentotaxis, and K -wiring. This study was conducted to assess the functional outcome of a novel percutaneous 5-pin technique in distal radius fractures. Materials and methods: This is a prospective observational study over 16 months from January 2019 to May 2020. Novel percutaneous 5-pin technique in a sequential configuration following a closed reduction was performed, followed by physiotherapy, and functional outcome was assessed at 6, 12, and 28 weeks following K -wire removal using Cooney’s modification of Green and Obrien scoring and evaluated for functional status, pin loosening, tendon impalement, and nerve injury. Results: All 20 patients were assessed. The mean age of patients was 47.15 years, 10 being females, with road traffic accidents being the major mode of injury. All patients were followed up for 6 months post- K -wire removal and 90% of patients had good to the excellent outcome and 10% of patients had fair to bad outcome with a functional range of supination and pronation movements. All fracture unions were satisfactory and four patients (20%) developed minor complications. None of them developed tendon impalement or nerve injuries. Conclusion: The novel percutaneous 5-pin technique includes two additional ulnoradial wires which provide superior rotational stability and avoid the chance of late collapse and maintain radial height, unlike conventional K -wire techniques. Thus, avoiding the need for more invasive techniques and allows early mobilization of wrist and fingers preventing stiffness, resulting in an excellent outcome.
桡骨远端骨折新型5针内固定及其功能评估
背景:几十年来,桡骨远端骨折一直是一个备受争议的话题。治疗选择包括POP铸造、电镀、带或不带韧带滑脱的外固定和K线。本研究旨在评估新型经皮5针技术治疗桡骨远端骨折的功能结果。材料和方法:这是一项为期16个月的前瞻性观察性研究,时间为2019年1月至2020年5月。采用闭合复位后的新型经皮5针序贯技术,然后进行物理治疗,并在K针取出后的6、12和28周使用Cooney改良的Green和Obrien评分评估功能结果,并评估功能状态、针松动、肌腱穿刺和神经损伤。结果:20例患者均获得评估。患者平均年龄47.15岁,女性10例,以道路交通事故为主要伤害方式。所有患者在K针拔除后随访6个月,90%的患者预后良好至极好,10%的患者预后一般至差,旋前和旋前运动功能范围正常。所有患者骨折愈合满意,4例(20%)出现轻微并发症。他们都没有出现肌腱刺痛或神经损伤。结论:与传统的K针技术不同,新型经皮5针技术包括两根额外的尺骨线,提供了更好的旋转稳定性,避免了晚期塌陷的机会,并保持了桡骨高度。因此,避免了更多侵入性技术的需要,并允许手腕和手指的早期活动,防止僵硬,产生良好的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信