Tomohiko Yamamoto, Akihisa Iwasaki, K. Kawamura, Shinichiro Matsubara, Hidenori Harada
{"title":"Fast Reactor Core Seismic Experiment and Analysis Under Strong Excitation","authors":"Tomohiko Yamamoto, Akihisa Iwasaki, K. Kawamura, Shinichiro Matsubara, Hidenori Harada","doi":"10.1115/PVP2018-84466","DOIUrl":null,"url":null,"abstract":"In design of fast reactor (FR) core components, seismic response must be evaluated in order to ensure the structural integrity. Thus, a core seismic analysis method has been developed to evaluate 3D core vibration behavior considering fluid structure interaction and vertical displacement (upward).\n Thirty seven 1/1.5 scale core element models which shape hexagonal-arrangement were used to validate the core element vibration analysis code in three dimensions (REVIAN-3D). Based on the test data, the newly incorporated analysis model has been verified to respond to strong excitation.","PeriodicalId":180537,"journal":{"name":"Volume 8: Seismic Engineering","volume":"365 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 8: Seismic Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/PVP2018-84466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In design of fast reactor (FR) core components, seismic response must be evaluated in order to ensure the structural integrity. Thus, a core seismic analysis method has been developed to evaluate 3D core vibration behavior considering fluid structure interaction and vertical displacement (upward).
Thirty seven 1/1.5 scale core element models which shape hexagonal-arrangement were used to validate the core element vibration analysis code in three dimensions (REVIAN-3D). Based on the test data, the newly incorporated analysis model has been verified to respond to strong excitation.