Comparative Study of Hyperspectral Aquisition Technique in Total Soluble Content and pH Measurement in Honey

Advendio Desandros, A. H. Saputro
{"title":"Comparative Study of Hyperspectral Aquisition Technique in Total Soluble Content and pH Measurement in Honey","authors":"Advendio Desandros, A. H. Saputro","doi":"10.1109/EIConCIT.2018.8878546","DOIUrl":null,"url":null,"abstract":"Transmittance and reflectance modes are the two most common technique used for investigating liquid psychochemical properties based on optical spectra. In the case of honey characterization, this research performed to show a comparison between both modes to measure honey’s Total Soluble Solids and pH based on the Vis-NIR hyperspectral imaging system. The system consists of Specim FX10 hyperspectral camera with 448 bands (400-1000nm), three 200 W halogen lamps, a light diffuser, a motor slider, and a PC. Then, a Partial Least Square Regression (PLSR) algorithm applied to predict measured values based on the acquired transmittance and reflectance spectrum. Performance of each technique tested by tenfold Cross Validation, which randomly grouping the dataset into ten partitions. Samples is prepared from 28 different honey types with varied colors, placed in 5 cm diameter Petri dishes at 10 ml volume. Performance of each technique measured by R2 and a Root Mean Square Percentage Error (RMSPE) score. Transmittance mode results in R2 of 0.93 and 0.80, RMSPE of 1.06% and 5.36% for total soluble solid content and pH measurement. For similar measured properties, reflectance mode results in R2 of 0.94 and 0.82, RMSPE of1.01% and 5.23%. In this research, reflectance mode performs slightly better than transmittance mode in the measurement of Total Soluble Solids and pH in honey samples.","PeriodicalId":424909,"journal":{"name":"2018 2nd East Indonesia Conference on Computer and Information Technology (EIConCIT)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 2nd East Indonesia Conference on Computer and Information Technology (EIConCIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIConCIT.2018.8878546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Transmittance and reflectance modes are the two most common technique used for investigating liquid psychochemical properties based on optical spectra. In the case of honey characterization, this research performed to show a comparison between both modes to measure honey’s Total Soluble Solids and pH based on the Vis-NIR hyperspectral imaging system. The system consists of Specim FX10 hyperspectral camera with 448 bands (400-1000nm), three 200 W halogen lamps, a light diffuser, a motor slider, and a PC. Then, a Partial Least Square Regression (PLSR) algorithm applied to predict measured values based on the acquired transmittance and reflectance spectrum. Performance of each technique tested by tenfold Cross Validation, which randomly grouping the dataset into ten partitions. Samples is prepared from 28 different honey types with varied colors, placed in 5 cm diameter Petri dishes at 10 ml volume. Performance of each technique measured by R2 and a Root Mean Square Percentage Error (RMSPE) score. Transmittance mode results in R2 of 0.93 and 0.80, RMSPE of 1.06% and 5.36% for total soluble solid content and pH measurement. For similar measured properties, reflectance mode results in R2 of 0.94 and 0.82, RMSPE of1.01% and 5.23%. In this research, reflectance mode performs slightly better than transmittance mode in the measurement of Total Soluble Solids and pH in honey samples.
高光谱获取技术测定蜂蜜中总可溶性含量和pH值的比较研究
透射和反射模式是基于光谱研究液体心理化学性质最常用的两种技术。以蜂蜜表征为例,本研究展示了基于Vis-NIR高光谱成像系统测量蜂蜜总可溶性固形物和pH值的两种模式之间的比较。该系统由448个波段(400-1000nm)的specm FX10高光谱相机、3个200w卤素灯、一个漫射器、一个电机滑块和一台PC组成。然后,采用偏最小二乘回归(PLSR)算法,根据获取的透射光谱和反射光谱预测测量值。每种技术的性能通过十次交叉验证进行测试,该交叉验证将数据集随机分组为十个分区。样品由28种不同颜色的蜂蜜制成,放置在直径5厘米的培养皿中,体积为10毫升。通过R2和均方根百分比误差(RMSPE)评分来衡量每种技术的性能。透过率模式测定的总可溶性固形物含量和pH值的R2分别为0.93和0.80,RMSPE分别为1.06%和5.36%。对于类似的测量性质,反射模式的结果R2分别为0.94和0.82,RMSPE分别为1.01%和5.23%。在本研究中,反射模式比透射模式在测量蜂蜜样品中的总可溶性固体和pH值时表现略好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信