J. M. Kumbhare, Ankush Deshmukh, M. Renge, Kundan Kumar
{"title":"THIPWM technique applied to three level ANPC converter for grid tied PV applications","authors":"J. M. Kumbhare, Ankush Deshmukh, M. Renge, Kundan Kumar","doi":"10.1109/ICTFCEN.2016.8052730","DOIUrl":null,"url":null,"abstract":"In recent years, the majority of the research has focused on grid-tied transformerless PV inverters, more capable than traditional grid-tied line transformer-based PV inverters, but more critical from a power quality point of view, especially in terms of common mode voltage and ground leakage current. Neutral point clamped (NPC) converters have recently gained popularity due to high efficiency and inherently low ground leakage current. This paper presents the three level active NPC (3L-ANPC) topology for grid tied PV applications with a third harmonic injection PWM strategy that allows to increase the magnitude of sinusoidal modulating wave by 15.5 % which improves dc link utilization. Simulation is carried out in Matlab/Simulink environment which confirms the effectiveness of the proposed converter.","PeriodicalId":339848,"journal":{"name":"2016 21st Century Energy Needs - Materials, Systems and Applications (ICTFCEN)","volume":"54 4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 21st Century Energy Needs - Materials, Systems and Applications (ICTFCEN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICTFCEN.2016.8052730","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In recent years, the majority of the research has focused on grid-tied transformerless PV inverters, more capable than traditional grid-tied line transformer-based PV inverters, but more critical from a power quality point of view, especially in terms of common mode voltage and ground leakage current. Neutral point clamped (NPC) converters have recently gained popularity due to high efficiency and inherently low ground leakage current. This paper presents the three level active NPC (3L-ANPC) topology for grid tied PV applications with a third harmonic injection PWM strategy that allows to increase the magnitude of sinusoidal modulating wave by 15.5 % which improves dc link utilization. Simulation is carried out in Matlab/Simulink environment which confirms the effectiveness of the proposed converter.