{"title":"[Echocardiographic diagnosis of thrombus on a Hancock bioprosthesis in mitral position following endocarditis (author's transl)].","authors":"W Daniel,&nbsp;H Klein,&nbsp;H Oelert,&nbsp;K Gahl,&nbsp;P Lichtlen","doi":"10.1055/s-0028-1096664","DOIUrl":null,"url":null,"abstract":"<p><p>Acute stenosis of a Hancock bioprosthesis in mitral position was found eight months after surgery and three months following septic periproctitic abscess in a 59 year old woman. Echocardiography revealed almost complete valve obstruction by thrombus formation: unusual dense and inhomogenous structures between the anterior and posterior stent echos of the prosthesis were seen in systole as well as in diastole. Echocardiography appears to be a useful non-invasive method for detection of the rare thrombotic complications in Hancock bioprostheses.</p>","PeriodicalId":22981,"journal":{"name":"Thoraxchirurgie, vaskulare Chirurgie","volume":"26 6","pages":"413-7"},"PeriodicalIF":0.0000,"publicationDate":"1978-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0028-1096664","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thoraxchirurgie, vaskulare Chirurgie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0028-1096664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Acute stenosis of a Hancock bioprosthesis in mitral position was found eight months after surgery and three months following septic periproctitic abscess in a 59 year old woman. Echocardiography revealed almost complete valve obstruction by thrombus formation: unusual dense and inhomogenous structures between the anterior and posterior stent echos of the prosthesis were seen in systole as well as in diastole. Echocardiography appears to be a useful non-invasive method for detection of the rare thrombotic complications in Hancock bioprostheses.

心内膜炎后二尖瓣位置汉考克生物假体血栓的超声心动图诊断(作者简介)。
摘要一例59岁女性患者在二尖瓣位置的汉考克生物假体在手术后8个月和脓毒性直肠周围脓肿后3个月出现急性狭窄。超声心动图显示血栓形成几乎完全阻塞瓣膜:在收缩期和舒张期假体前后支架回声之间可见异常致密和不均匀的结构。超声心动图似乎是一种有用的非侵入性方法检测罕见的血栓性并发症的汉考克生物假体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信