[Artery end to end anastomoses with screw-dense-fixation-rings (author's transl)].

P H Schomacher
{"title":"[Artery end to end anastomoses with screw-dense-fixation-rings (author's transl)].","authors":"P H Schomacher","doi":"10.1055/s-0028-1097072","DOIUrl":null,"url":null,"abstract":"<p><p>In study of screw-dense-fixation-ring method in 15 cases of a dog's femoral artery, end to end, was reconstructed. The anastomoses is achieved by vessels of 3 - 6 mm diameter. Within a period of 1 - 6 months post-operatively, average of 3 months, angiographic control of all cases showed no complications such as aneurysm or stricture. The construction of screw-dense-fixation-ring seems to give a considerable result, because the power which is keeping the rings together, can be controlled.</p>","PeriodicalId":22981,"journal":{"name":"Thoraxchirurgie, vaskulare Chirurgie","volume":"25 6","pages":"422-6"},"PeriodicalIF":0.0000,"publicationDate":"1977-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0028-1097072","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thoraxchirurgie, vaskulare Chirurgie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0028-1097072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In study of screw-dense-fixation-ring method in 15 cases of a dog's femoral artery, end to end, was reconstructed. The anastomoses is achieved by vessels of 3 - 6 mm diameter. Within a period of 1 - 6 months post-operatively, average of 3 months, angiographic control of all cases showed no complications such as aneurysm or stricture. The construction of screw-dense-fixation-ring seems to give a considerable result, because the power which is keeping the rings together, can be controlled.

[动脉端到端吻合螺钉密集固定环(作者图)]。
对15例犬股动脉进行了端对端螺钉密集固定环法重建。吻合是由直径3 - 6mm的血管完成的。术后1 ~ 6个月,平均3个月,所有病例血管造影控制均未见动脉瘤、狭窄等并发症。螺旋密集固定环的构造似乎产生了相当大的效果,因为使环保持在一起的力量是可以控制的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信