{"title":"The quantitative indicators of 750kV Porcelain Insulator in UV detection based on artificial contamination test","authors":"Cai-jing, N. Zhang, Ma-Zhong, Peng-Min, Xiaoguang Shang, Z. Jia, Linjun Wang","doi":"10.1109/ICD.2016.7547652","DOIUrl":null,"url":null,"abstract":"In the process of the operation of 750kV transmission line, the insulator should be detected in time and effectively. As a fast and efficient method to detect the discharge of insulators, the ultraviolet detection technique is very important in the detection of 750kV insulator. In this paper, we analyzed the ultraviolet detection result of the 750kV Porcelain Insulator artificial contamination test, and then defined two indicators, relative fluctuation of photon number and mean value of spot area to evaluate the severity of discharge. The two indicators, UV photon number and UV spot area were studied in this paper. It is found that UV photon number and UV spot area couldn't evaluate the severity of insulator discharge quantitatively, but relative fluctuation of photon number and stage mean value of spot area could quantitatively evaluate the severity of insulator discharge. The results of this paper is of great significance to the application of UV detection technology in the detection of 750kV insulator.","PeriodicalId":306397,"journal":{"name":"2016 IEEE International Conference on Dielectrics (ICD)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD.2016.7547652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In the process of the operation of 750kV transmission line, the insulator should be detected in time and effectively. As a fast and efficient method to detect the discharge of insulators, the ultraviolet detection technique is very important in the detection of 750kV insulator. In this paper, we analyzed the ultraviolet detection result of the 750kV Porcelain Insulator artificial contamination test, and then defined two indicators, relative fluctuation of photon number and mean value of spot area to evaluate the severity of discharge. The two indicators, UV photon number and UV spot area were studied in this paper. It is found that UV photon number and UV spot area couldn't evaluate the severity of insulator discharge quantitatively, but relative fluctuation of photon number and stage mean value of spot area could quantitatively evaluate the severity of insulator discharge. The results of this paper is of great significance to the application of UV detection technology in the detection of 750kV insulator.
基于人工污染试验的750kV瓷绝缘子紫外检测定量指标
在750kV输电线路运行过程中,应及时有效地对绝缘子进行检测。紫外检测技术作为一种快速、高效的绝缘子放电检测方法,在750kV绝缘子放电检测中占有十分重要的地位。本文对750kV瓷绝缘子人工污染试验的紫外检测结果进行了分析,定义了光子数相对波动和光斑面积平均值两个指标来评价放电的严重程度。对紫外光子数和紫外光斑面积这两个指标进行了研究。发现紫外光子数和紫外光斑面积不能定量评价绝缘子放电的严重程度,但光子数和光斑面积阶段平均值的相对波动可以定量评价绝缘子放电的严重程度。本文的研究结果对紫外检测技术在750kV绝缘子检测中的应用具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信