Non-Invasive Blood Pressure and Heart Rate Sensing Using Photoplethysmogram Sensor

Nur Intan Fathehah Mohd Lahil, F. Wong, A. Chekima, S. Abang, Normah Awang Besar, A. Kiring, Yew Hoe Tung, C. S. Kheau, J. Dargham
{"title":"Non-Invasive Blood Pressure and Heart Rate Sensing Using Photoplethysmogram Sensor","authors":"Nur Intan Fathehah Mohd Lahil, F. Wong, A. Chekima, S. Abang, Normah Awang Besar, A. Kiring, Yew Hoe Tung, C. S. Kheau, J. Dargham","doi":"10.1109/CSPA52141.2021.9377302","DOIUrl":null,"url":null,"abstract":"The non-invasive and cuffless blood pressure (BP) and heart rate (HR) monitoring device is designed to help people to monitor their BP and HR regularly. A Photoplethysmogram (PPG) sensor was used to obtain the PPG signal needed for the BP and HR calculations. The performance of the BP and HR monitoring device was tested based on the accuracy of the readings obtained by comparing readings from the proposed device with the readings obtained by clinical instruments. The factors that are affecting the accuracy of the sensor are also discussed in this paper.","PeriodicalId":194655,"journal":{"name":"2021 IEEE 17th International Colloquium on Signal Processing & Its Applications (CSPA)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 17th International Colloquium on Signal Processing & Its Applications (CSPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CSPA52141.2021.9377302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The non-invasive and cuffless blood pressure (BP) and heart rate (HR) monitoring device is designed to help people to monitor their BP and HR regularly. A Photoplethysmogram (PPG) sensor was used to obtain the PPG signal needed for the BP and HR calculations. The performance of the BP and HR monitoring device was tested based on the accuracy of the readings obtained by comparing readings from the proposed device with the readings obtained by clinical instruments. The factors that are affecting the accuracy of the sensor are also discussed in this paper.
利用光电容积描记传感器进行无创血压和心率传感
这种无创、无袖带的血压(BP)和心率(HR)监测装置旨在帮助人们定期监测血压和HR。Photoplethysmogram (PPG)传感器用于获取BP和HR计算所需的PPG信号。通过将所提出的装置的读数与临床仪器的读数进行比较,获得读数的准确性,从而测试血压和心率监测装置的性能。本文还讨论了影响传感器精度的因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信