A comparison of diffusive light reflectance from in vitro and in vivo media

M. R. Muller, L. Ostrander
{"title":"A comparison of diffusive light reflectance from in vitro and in vivo media","authors":"M. R. Muller, L. Ostrander","doi":"10.1109/NEBC.1994.305152","DOIUrl":null,"url":null,"abstract":"The shape of surface reflectance curves is compared for a test medium and for the surface of the human limb. A modulated light spot was incident on the surface of the media and mean reflectance was measured at light source-detector separations ranging from 2.5 mm to 34.5 mm. The in vitro model was constructed to approximate a diffusive layered biological medium. The diffusive properties of the model were changed at depth. Both the in vitro and in vivo results are compared with those predicted by diffusion theory for a uniform diffusive medium. The results indicate that the in vitro medium appears to capture the optical behavior of an in vivo medium for surface measurements out to five diffusion lengths. In addition, the data from both media are matched to the uniform diffusive medium predicted by diffusion theory with good agreement at large source-detector separations.<<ETX>>","PeriodicalId":117140,"journal":{"name":"Proceedings of 1994 20th Annual Northeast Bioengineering Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 20th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1994.305152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The shape of surface reflectance curves is compared for a test medium and for the surface of the human limb. A modulated light spot was incident on the surface of the media and mean reflectance was measured at light source-detector separations ranging from 2.5 mm to 34.5 mm. The in vitro model was constructed to approximate a diffusive layered biological medium. The diffusive properties of the model were changed at depth. Both the in vitro and in vivo results are compared with those predicted by diffusion theory for a uniform diffusive medium. The results indicate that the in vitro medium appears to capture the optical behavior of an in vivo medium for surface measurements out to five diffusion lengths. In addition, the data from both media are matched to the uniform diffusive medium predicted by diffusion theory with good agreement at large source-detector separations.<>
体外和体内介质的漫射光反射率比较
比较了测试介质和人体肢体表面的反射曲线形状。在介质表面入射一个调制光斑,在光源-探测器距离为2.5 mm至34.5 mm处测量平均反射率。体外模型近似于扩散的层状生物培养基。模型的扩散特性在深度处发生了变化。体内和体外实验结果均与均匀扩散介质的扩散理论预测结果进行了比较。结果表明,在体外培养基似乎捕捉到一个在体内介质的光学行为表面测量出五个扩散长度。此外,两种介质的数据与扩散理论预测的均匀扩散介质相匹配,在较大的源-探测器距离处具有良好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信