Attenuation of 900 MHz and 1.35 GHz signal inside room of a building

A. Chandra, P. Chandra
{"title":"Attenuation of 900 MHz and 1.35 GHz signal inside room of a building","authors":"A. Chandra, P. Chandra","doi":"10.1109/ICPWC.1997.655507","DOIUrl":null,"url":null,"abstract":"The performance of indoor communication services offering the transfer of voice and data inside a building is severely affected by the presence of a large number of scatterers/reflectors. The paper reports the results of propagation measurements at 900 MHz and 1.35 GHz conducted inside a room on a floor of a office-cum-laboratory building. From the measured data, the path loss exponent, standard deviation, RMS time delay and coherence bandwidth are determined.","PeriodicalId":166667,"journal":{"name":"1997 IEEE International Conference on Personal Wireless Communications (Cat. No.97TH8338)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE International Conference on Personal Wireless Communications (Cat. No.97TH8338)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPWC.1997.655507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The performance of indoor communication services offering the transfer of voice and data inside a building is severely affected by the presence of a large number of scatterers/reflectors. The paper reports the results of propagation measurements at 900 MHz and 1.35 GHz conducted inside a room on a floor of a office-cum-laboratory building. From the measured data, the path loss exponent, standard deviation, RMS time delay and coherence bandwidth are determined.
建筑物室内900 MHz及1.35 GHz信号的衰减
提供在建筑物内传送语音和数据的室内通信服务的性能受到大量散射/反射器的严重影响。本文报道了在办公兼实验室大楼的一层房间内进行的900 MHz和1.35 GHz传播测量的结果。根据测量数据,确定了路径损耗指数、标准偏差、均方根时延和相干带宽。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信