{"title":"Considerations in maintaining process continuity during voltage dips while protecting motors","authors":"S. Mulukutla, E.M. Gulachenski","doi":"10.1109/ICPS.1988.10974","DOIUrl":null,"url":null,"abstract":"The problem of transients and criteria for safe reclosing or transfer of several motors on the same bus are presented. References are given for modeling induction and synchronous motors, and also for determining the currents and torques due to out-of-phase reclosing. Various protective schemes against out-of-phase reclosing and transfer as well as methods of riding through voltage dips are discussed. Application of a particular method depends on the individual characteristics of each electrical system and the process that it serves.<<ETX>>","PeriodicalId":201639,"journal":{"name":"Conference Record, Industrial and Commercial Power Systems Technical Conference, 1988.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record, Industrial and Commercial Power Systems Technical Conference, 1988.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1988.10974","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The problem of transients and criteria for safe reclosing or transfer of several motors on the same bus are presented. References are given for modeling induction and synchronous motors, and also for determining the currents and torques due to out-of-phase reclosing. Various protective schemes against out-of-phase reclosing and transfer as well as methods of riding through voltage dips are discussed. Application of a particular method depends on the individual characteristics of each electrical system and the process that it serves.<>
在电压下降期间保持过程连续性的考虑因素,同时保护电机
提出了多台电动机在同一母线上安全合闸或转移的暂态问题和准则。本文为异步电动机和同步电动机的建模提供了参考,也为确定由于失相重合闸引起的电流和转矩提供了参考。讨论了各种防止异相重合闸和转移的保护方案以及通过电压跌落的方法。一种特定方法的应用取决于每个电气系统的个别特性及其所服务的过程
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信