A Zelman, M White, K Acker, T Neal, R Parsons, D Gisser
{"title":"A simple method for incorporating single pass dialysate delivery and controlled ultrafiltration with the RP-6 high flux dialyzer.","authors":"A Zelman, M White, K Acker, T Neal, R Parsons, D Gisser","doi":"10.3109/08860227909063942","DOIUrl":null,"url":null,"abstract":"<p><p>A simple hemodialysis protocol has been developed to permit significant \"middle molecule\" clearance, yet retain normal low molecular weight clearance. The high flux RP-6 dialyzer has been combined with a single pass dialysate delivery system to provide accurate control of ultrafiltration without resorting to specialized or expensive equipment. By operating the RP-6 in the co-current mode, a simple valve on the dialysate output can be used to regulate ultrafiltration. At QB = 200 ml/min and QD = 500 ml/min, CU = 127 ml/min and CB12 = 56 ml/min at zero ultrafiltration rate; these values increase considerably with ultrafiltration. This protocol offers dialysis centers with standard equipment the opportunity to use high flux membranes in a routine manner.</p>","PeriodicalId":75998,"journal":{"name":"Journal of dialysis","volume":"3 2-3","pages":"219-35"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/08860227909063942","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dialysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/08860227909063942","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
A simple hemodialysis protocol has been developed to permit significant "middle molecule" clearance, yet retain normal low molecular weight clearance. The high flux RP-6 dialyzer has been combined with a single pass dialysate delivery system to provide accurate control of ultrafiltration without resorting to specialized or expensive equipment. By operating the RP-6 in the co-current mode, a simple valve on the dialysate output can be used to regulate ultrafiltration. At QB = 200 ml/min and QD = 500 ml/min, CU = 127 ml/min and CB12 = 56 ml/min at zero ultrafiltration rate; these values increase considerably with ultrafiltration. This protocol offers dialysis centers with standard equipment the opportunity to use high flux membranes in a routine manner.