Design of Digital IIR Filter for Noise Reduction in ECG Signal

Nalini Singh, S. Ayub, J. Saini
{"title":"Design of Digital IIR Filter for Noise Reduction in ECG Signal","authors":"Nalini Singh, S. Ayub, J. Saini","doi":"10.1109/CICN.2013.45","DOIUrl":null,"url":null,"abstract":"Electrocardiogram (ECG) signal has been widely used in cardiac pathology to detect heart disease. A digital infinite-impulse response (IIR) filter design is proposed in this paper. This includes an implementation and evaluation of butter worth low pass infinite impulse response filter method to remove high frequency noise and for this filter is applied to noisy ECG data sample and original sample are taken as reference signal. The suggested method considers the magnitude response for choosing the cutoff frequency and the FFT spectrum estimate response to find the lowest filter order. The structure and the coefficients of the digital IIR filter are designed using FDA tool in MATLAB. The filter output's average power before and after filtration are calculated using FFT and for simulation of this filter, the hardware is designed using micro controller At mega 16 A. For hardware designing the samples taken are record no. 108 and record no. 119 (taken from MIT-BIH database, ML II signal). Here samples are taken from MIT-BIH arrhythmia database (mitdb) ML II are used.","PeriodicalId":415274,"journal":{"name":"2013 5th International Conference on Computational Intelligence and Communication Networks","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 5th International Conference on Computational Intelligence and Communication Networks","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICN.2013.45","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

Electrocardiogram (ECG) signal has been widely used in cardiac pathology to detect heart disease. A digital infinite-impulse response (IIR) filter design is proposed in this paper. This includes an implementation and evaluation of butter worth low pass infinite impulse response filter method to remove high frequency noise and for this filter is applied to noisy ECG data sample and original sample are taken as reference signal. The suggested method considers the magnitude response for choosing the cutoff frequency and the FFT spectrum estimate response to find the lowest filter order. The structure and the coefficients of the digital IIR filter are designed using FDA tool in MATLAB. The filter output's average power before and after filtration are calculated using FFT and for simulation of this filter, the hardware is designed using micro controller At mega 16 A. For hardware designing the samples taken are record no. 108 and record no. 119 (taken from MIT-BIH database, ML II signal). Here samples are taken from MIT-BIH arrhythmia database (mitdb) ML II are used.
用于心电信号降噪的数字IIR滤波器设计
心电图信号在心脏病理学中被广泛应用于检测心脏疾病。提出了一种数字无限脉冲响应(IIR)滤波器设计方案。本文介绍了一种用于去除高频噪声的低通无限脉冲响应滤波方法的实现和评价,并将该滤波器应用于有噪声的心电数据样本,并以原始样本作为参考信号。该方法考虑了选择截止频率的幅值响应和FFT频谱估计响应来寻找最低滤波器阶数。利用MATLAB中的FDA工具设计了数字IIR滤波器的结构和系数。利用FFT计算滤波前后滤波器输出的平均功率,并采用mega16 A的微控制器设计硬件,对滤波器进行仿真。对于硬件设计,所取样品为记录编号。108号和记录号。119(取自MIT-BIH数据库,ML II信号)。这里的样本取自MIT-BIH心律失常数据库(mitdb) ML II。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信