{"title":"Control of islanded inverter interfaced Distributed Generation units for power quality improvement","authors":"A. Ghadimi, F. Razavi, R. Ghaffarpour","doi":"10.1109/ICHQP.2010.5625469","DOIUrl":null,"url":null,"abstract":"A load sharing control strategy for operating of a distribution system consisting of multiple inverter interfaced Distributed Generation (DG) unit when isolated from a main utility in order to improve continuity and quality of electricity to important loads is presented and tested in this paper. In the stand-alone network, a Master DG unit exists as voltage and frequency reference and the other units work on synchronize with this unit and produce energy to loads. A supervisory controller defines all Distributed Generation units' reference powers with consideration of system and unit normal rating in order to maintain reliable and high quality power to the loads. Simulation results on IEEE 37 node test system verify that the proposed control scheme is effective for stable working of the stand-alone network.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A load sharing control strategy for operating of a distribution system consisting of multiple inverter interfaced Distributed Generation (DG) unit when isolated from a main utility in order to improve continuity and quality of electricity to important loads is presented and tested in this paper. In the stand-alone network, a Master DG unit exists as voltage and frequency reference and the other units work on synchronize with this unit and produce energy to loads. A supervisory controller defines all Distributed Generation units' reference powers with consideration of system and unit normal rating in order to maintain reliable and high quality power to the loads. Simulation results on IEEE 37 node test system verify that the proposed control scheme is effective for stable working of the stand-alone network.
基于孤岛逆变器接口的分布式发电机组电能质量控制
本文提出了一种由多个逆变器接口的分布式发电机组组成的配电系统在与主电源隔离时的负荷分担控制策略,以提高重要负荷的电力连续性和质量。在独立电网中,主DG机组作为电压和频率参考而存在,其他机组与该机组同步工作并向负载产生能量。监控控制器综合考虑系统和机组的正常额定值,定义所有分布式发电机组的参考功率,以保证向负荷提供可靠、高质量的电力。在IEEE 37节点测试系统上的仿真结果验证了所提出的控制方案对单机网络的稳定运行是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信