Series-Connected Adaptive Stabilizer for the Grid Connected Inverter at Weak Grid

Xin Zhang, Huanyue Liao
{"title":"Series-Connected Adaptive Stabilizer for the Grid Connected Inverter at Weak Grid","authors":"Xin Zhang, Huanyue Liao","doi":"10.1109/ACEPT.2018.8610801","DOIUrl":null,"url":null,"abstract":"This paper proposes a series-connected adaptive stabilizer (SAS) to fix the instability problem between the grid-connected inverter (GCI) and the weak grid via shaping the grid impedance. Different from the traditional stabilization method, the SAS does not need to know the information about the GCI, therefore, it can be treated as a module stabilization method. In addition, since the SAS is in series with the GCI and the grid impedance, it only goes through very small power. Moreover, the SAS is realized by a very simple adaptive current controller without any additional phase locked loop (PLL) and hence, is very easy to be implemented in the real world. Besides, the SAS also can match different GCIs automatically. Finally, an LCL type GCI is tested to verify the correctness of the proposed SAS.","PeriodicalId":296432,"journal":{"name":"2018 Asian Conference on Energy, Power and Transportation Electrification (ACEPT)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Asian Conference on Energy, Power and Transportation Electrification (ACEPT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACEPT.2018.8610801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper proposes a series-connected adaptive stabilizer (SAS) to fix the instability problem between the grid-connected inverter (GCI) and the weak grid via shaping the grid impedance. Different from the traditional stabilization method, the SAS does not need to know the information about the GCI, therefore, it can be treated as a module stabilization method. In addition, since the SAS is in series with the GCI and the grid impedance, it only goes through very small power. Moreover, the SAS is realized by a very simple adaptive current controller without any additional phase locked loop (PLL) and hence, is very easy to be implemented in the real world. Besides, the SAS also can match different GCIs automatically. Finally, an LCL type GCI is tested to verify the correctness of the proposed SAS.
弱电网并网逆变器串联自适应稳定器
本文提出了一种串联自适应稳定器(SAS),通过对电网阻抗的塑造来解决并网逆变器与弱电网之间的不稳定问题。与传统的稳定化方法不同,SAS不需要知道GCI的信息,因此可以将其视为模块稳定化方法。此外,由于SAS与GCI和网格阻抗是串联的,因此它只通过非常小的功率。此外,SAS是由一个非常简单的自适应电流控制器实现的,没有任何额外的锁相环(PLL),因此,在现实世界中非常容易实现。此外,SAS还可以自动匹配不同的gci。最后,对LCL型GCI进行了测试,以验证所提出的SAS的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信