{"title":"Precision automated capacitance bridges for the low frequency range at the PTB","authors":"R. Hanke, J. Melcher, A. Muciek, R. Koster","doi":"10.1109/CPEM.1994.333188","DOIUrl":null,"url":null,"abstract":"Two computer-controlled capacitance bridges for different fields of application have been developed at the PTB. The first one, the universal bridge, works in the capacitance range of less than 1 pF up to 1 /spl mu/F and in a frequency range up to 1 kHz, The total calculated relative uncertainties (2/spl sigma/) are in the order of 5/spl middot/10/sup -6/ and 20/spl middot/10/sup -6/. The second one, the fixed ratio bridge, calibrates primary standards with capacitance values from 1 pF to 1 nF in 1:1, 1:2, 1:5 or 1:10 steps at frequencies from 100 Hz to 10 kHz. The relative uncertainty of one 1:10 step at a frequency of 1592 Hz is estimated to be 3/spl middot/10/sup -8/ (1/spl sigma/).<<ETX>>","PeriodicalId":388647,"journal":{"name":"Proceedings of Conference on Precision Electromagnetic Measurements Digest","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Conference on Precision Electromagnetic Measurements Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.1994.333188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Two computer-controlled capacitance bridges for different fields of application have been developed at the PTB. The first one, the universal bridge, works in the capacitance range of less than 1 pF up to 1 /spl mu/F and in a frequency range up to 1 kHz, The total calculated relative uncertainties (2/spl sigma/) are in the order of 5/spl middot/10/sup -6/ and 20/spl middot/10/sup -6/. The second one, the fixed ratio bridge, calibrates primary standards with capacitance values from 1 pF to 1 nF in 1:1, 1:2, 1:5 or 1:10 steps at frequencies from 100 Hz to 10 kHz. The relative uncertainty of one 1:10 step at a frequency of 1592 Hz is estimated to be 3/spl middot/10/sup -8/ (1/spl sigma/).<>
精密自动电容桥在PTB的低频范围
在PTB开发了两个计算机控制的电容桥,用于不同的应用领域。第一种是通用电桥,工作在电容范围小于1 pF到1 /spl mu/F,频率范围高达1 kHz,计算出的总相对不确定度(2/spl sigma/)为5/spl middot/10/sup -6/和20/spl middot/10/sup -6/。第二种是固定比率桥,在100hz到10khz的频率范围内,以1:1、1:2、1:5或1:10步进校准电容值从1pf到1nf的主要标准。在1592 Hz频率下,一个1:10阶跃的相对不确定度估计为3/spl middot/10/sup -8/ (1/spl sigma/)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信