En-face OCT microleakage investigation after laser-assisted dental hard tissue treatment

C. Todea, Cosmin Bălăbuc, C. Sinescu, M. Negruțiu, Laura Filip, A. Bradu, A. Podoleanu
{"title":"En-face OCT microleakage investigation after laser-assisted dental hard tissue treatment","authors":"C. Todea, Cosmin Bălăbuc, C. Sinescu, M. Negruțiu, Laura Filip, A. Bradu, A. Podoleanu","doi":"10.1117/12.814917","DOIUrl":null,"url":null,"abstract":"Purpose: To investigate using en-face Optical Coherence Tomography (OCT) the microleakage after Er:YAG laser cavity preparation. Material and Methods: Thirty single- and multi-rooted freshly extracted human teeth divided into two study groups, group I (laser) and group II (control), were used in this study. In group I, Class V cavities were prepared using laser on the buccal surface of each tooth. The laser device used was an Er:YAG laser (2940 nm, VSP, 250-320 mJ, 10-20 Hz). In group II, cavities were prepared conventionally and acid etched on the oral surface of the same tooth. All cavities were filled with composite resin. The cavity microleakage was investigated using en-face Optical Coherence Tomography prototype, based on transverse scanning and operating at 1300 nm. Results: The investigation demonstrated qualitatively the reduction of microleakage in cavities prepared with Er:YAG laser as compared to the control group, in which cavities were prepared conventionally. Conclusion: The en-face OCT method provided a superior non-invasive and real time investigation method, thus reducing the occurrence of secondary caries by early detection. Moreover, based on the results of this investigation, it may be concluded that Er:YAG laser-assisted cavity preparation leads to reduction of microleakage.","PeriodicalId":184459,"journal":{"name":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.814917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate using en-face Optical Coherence Tomography (OCT) the microleakage after Er:YAG laser cavity preparation. Material and Methods: Thirty single- and multi-rooted freshly extracted human teeth divided into two study groups, group I (laser) and group II (control), were used in this study. In group I, Class V cavities were prepared using laser on the buccal surface of each tooth. The laser device used was an Er:YAG laser (2940 nm, VSP, 250-320 mJ, 10-20 Hz). In group II, cavities were prepared conventionally and acid etched on the oral surface of the same tooth. All cavities were filled with composite resin. The cavity microleakage was investigated using en-face Optical Coherence Tomography prototype, based on transverse scanning and operating at 1300 nm. Results: The investigation demonstrated qualitatively the reduction of microleakage in cavities prepared with Er:YAG laser as compared to the control group, in which cavities were prepared conventionally. Conclusion: The en-face OCT method provided a superior non-invasive and real time investigation method, thus reducing the occurrence of secondary caries by early detection. Moreover, based on the results of this investigation, it may be concluded that Er:YAG laser-assisted cavity preparation leads to reduction of microleakage.
激光辅助牙硬组织治疗后的正面OCT微渗漏研究
目的:利用面光学相干断层扫描(OCT)研究Er:YAG激光腔制备后的微泄漏。材料与方法:将30颗新鲜拔除的人单根和多根牙齿分为激光组和对照组。在第一组,用激光在每颗牙齿的颊面制备V类空腔。激光器件为Er:YAG激光器(2940 nm, VSP, 250 ~ 320 mJ, 10 ~ 20 Hz)。在第二组中,常规制备空腔,并在同一颗牙齿的口腔表面进行酸蚀。所有空腔均用复合树脂填充。采用横向扫描的正面光学相干层析成像原型机,在1300 nm波长下对腔体微泄漏进行了研究。结果:与常规制备腔体的对照组相比,研究定性地证明了Er:YAG激光制备腔体的微泄漏减少。结论:正面OCT法是一种无创、实时的检查方法,早期发现可减少继发龋的发生。此外,基于本研究的结果,可以得出Er:YAG激光辅助空腔制备导致微泄漏减少的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信