C. Shakher, Md. Mosarraf Hossain, D. Mehta, G. Sheoran
{"title":"Measurement of temperature field in steady laminar free convection flow using digital holography","authors":"C. Shakher, Md. Mosarraf Hossain, D. Mehta, G. Sheoran","doi":"10.1117/12.814570","DOIUrl":null,"url":null,"abstract":"A method to measure the temperature by visualizing the laminar free convection flow of water is presented by using digital holography in lensless Fourier transform configuration. Temperature is measured within the boundary layer of the convective flow field. The deviation in temperature measured by this method and from that of obtained by thermocouple is within 2%.","PeriodicalId":191475,"journal":{"name":"International Symposium on Laser Metrology","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Laser Metrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.814570","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
A method to measure the temperature by visualizing the laminar free convection flow of water is presented by using digital holography in lensless Fourier transform configuration. Temperature is measured within the boundary layer of the convective flow field. The deviation in temperature measured by this method and from that of obtained by thermocouple is within 2%.