USE OF ACTIVE MICROORGANISM IN IMPROVING POND WATER QUALITY: CASE STUDY OF BEYTEPE POND

Fatma Ozkay, I. Tas, Hakan Ozkandan, A. Gunal, Tuğba Yeter, Ceren Gorgisen, Betul Iba Cakir, Bekir Kutlu, M. Inan, Ece Ates
{"title":"USE OF ACTIVE MICROORGANISM IN IMPROVING POND WATER QUALITY: CASE STUDY OF BEYTEPE POND","authors":"Fatma Ozkay, I. Tas, Hakan Ozkandan, A. Gunal, Tuğba Yeter, Ceren Gorgisen, Betul Iba Cakir, Bekir Kutlu, M. Inan, Ece Ates","doi":"10.47068/ctns.2022.v11i21.044","DOIUrl":null,"url":null,"abstract":"Water resources have been seriously polluted in terms of quality in the last hundred years, especially due to anthropogenic effects. The quality of the water in the storage structures (dam, lake, pond, etc.) has started to deteriorate due to the deterioration in the drainage basin, especially the insufficient feeding. In recent years, researches on the protection and improvement of the quality of water in storage structures have begun to increase. In this study, it was aimed to improve the water quality of Beytepe Pond located in the campus of the Turkish National Botanic Garden Directorate (TNBG) by using Active Microorganism (EM) in laboratory conditions. In the study, Baykal EM1, active microorganism, was used. For improvement water quality was used aerobic (A) and anaerobic (AN) systems in containers with a volume of 10 liters. EM was administered in 3 doses as 5, 10 and 20 ml L-1. pH, conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD) and chlorophyll-a values were measured in the pond water. Beytepe Pond water is 3rd class according to the US salinity laboratory salinity classification (USSL). COD and chlorophyll-a values exceed eutrophication limit values. At the beginning of the study, the raw water COD value was measured as 263 mg L-1. It was determined that 5 ml L-1 EM application was reduced up to 2 mg L-1 in anaerobic system application. The same application provided the best improvement in chlorophyll-a values. As a result of the study, it was observed that the EM application provided an improvement in the quality of the Beytepe Pond water.","PeriodicalId":254664,"journal":{"name":"Current Trends in Natural Sciences","volume":"494 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Trends in Natural Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47068/ctns.2022.v11i21.044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Water resources have been seriously polluted in terms of quality in the last hundred years, especially due to anthropogenic effects. The quality of the water in the storage structures (dam, lake, pond, etc.) has started to deteriorate due to the deterioration in the drainage basin, especially the insufficient feeding. In recent years, researches on the protection and improvement of the quality of water in storage structures have begun to increase. In this study, it was aimed to improve the water quality of Beytepe Pond located in the campus of the Turkish National Botanic Garden Directorate (TNBG) by using Active Microorganism (EM) in laboratory conditions. In the study, Baykal EM1, active microorganism, was used. For improvement water quality was used aerobic (A) and anaerobic (AN) systems in containers with a volume of 10 liters. EM was administered in 3 doses as 5, 10 and 20 ml L-1. pH, conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD) and chlorophyll-a values were measured in the pond water. Beytepe Pond water is 3rd class according to the US salinity laboratory salinity classification (USSL). COD and chlorophyll-a values exceed eutrophication limit values. At the beginning of the study, the raw water COD value was measured as 263 mg L-1. It was determined that 5 ml L-1 EM application was reduced up to 2 mg L-1 in anaerobic system application. The same application provided the best improvement in chlorophyll-a values. As a result of the study, it was observed that the EM application provided an improvement in the quality of the Beytepe Pond water.
活性微生物在改善池塘水质中的应用——以贝特坡池塘为例
近百年来,由于人类活动的影响,水资源质量受到了严重的污染。蓄水构筑物(坝、湖、塘等)的水质由于流域的恶化,特别是进料不足而开始恶化。近年来,对储水结构水质保护和改善的研究开始增多。本研究旨在通过在实验室条件下使用活性微生物(EM)改善位于土耳其国家植物园理事会(TNBG)校园的Beytepe池的水质。本研究采用活性微生物Baykal EM1。为了改善水质,在容积为10升的容器中使用好氧(A)和厌氧(AN)系统。EM分5、10、20 ml L-1 3次给药。测定了池塘水体pH、电导率(EC)、溶解氧(DO)、化学需氧量(COD)和叶绿素a。根据美国盐度实验室盐度分类(USSL), Beytepe池塘的水是第三类。COD和叶绿素a值超过富营养化极限值。研究开始时,测定原水COD值为263 mg L-1。经测定,在厌氧系统应用中,5ml L-1 EM应用可减少至2mg L-1。相同施用对叶绿素-a值的改善效果最好。研究结果表明,EM的应用改善了Beytepe池塘的水质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信