Influences of loading layout on parameters and coaxial cable coupling laws in reverberation chamber

Wang Shuqiao, W. Qingguo, Jia Rui
{"title":"Influences of loading layout on parameters and coaxial cable coupling laws in reverberation chamber","authors":"Wang Shuqiao, W. Qingguo, Jia Rui","doi":"10.1109/CSQRWC.2013.6657339","DOIUrl":null,"url":null,"abstract":"Through the test of field intensity, power and the S21 of reverberation chamber, the Q value and the independent sampling points with absorbing material loaded in different positions are calculated in this paper, and the result show that as the loading position varies the parameters of reverberation chamber mentioned above differ. And this paper presents the method of using network analyzer and electro-optical conversion equipment to test the laws of coaxial cable coupling. The impact of loadings on coaxial cable coupling is also analyzed.","PeriodicalId":355180,"journal":{"name":"2013 Cross Strait Quad-Regional Radio Science and Wireless Technology Conference","volume":"349 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Cross Strait Quad-Regional Radio Science and Wireless Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CSQRWC.2013.6657339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Through the test of field intensity, power and the S21 of reverberation chamber, the Q value and the independent sampling points with absorbing material loaded in different positions are calculated in this paper, and the result show that as the loading position varies the parameters of reverberation chamber mentioned above differ. And this paper presents the method of using network analyzer and electro-optical conversion equipment to test the laws of coaxial cable coupling. The impact of loadings on coaxial cable coupling is also analyzed.
加载布置对混响室参数及同轴电缆耦合规律的影响
本文通过对混响室的场强、功率和S21的测试,计算了不同位置加载吸波材料的Q值和独立采样点,结果表明,随着加载位置的不同,混响室的上述参数也不同。本文介绍了利用网络分析仪和电光转换设备测试同轴电缆耦合规律的方法。分析了载荷对同轴电缆耦合的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信