{"title":"Impact of the Symmetry of Coupling-Decoupling Networks on the Conducted Immunity Testing of PLC Modems","authors":"M. Rubinstein, A. Vukičević, F. Rachidi, J. Bermudez","doi":"10.1109/EMCZUR.2007.4388301","DOIUrl":null,"url":null,"abstract":"For conducted immunity testing, the injection of the test common mode signal is achieved by way of the couplingdecoupling network (CDN) whose symmetry is not defined in the standards. Due to the low symmetry of PLC cabling, part of the injected common mode test signal is converted into a differential mode signal that interferes with the wanted signal at the input of the modem being tested. We show in this paper that the expected bit error rates due to the differential mode current from the CDN are of the order of 1×10−5 to 5×10−5, which can be handled by coding and MAC ARQ procedures. We also show that it is unlikely that the differential mode signals from the CDN#2019;s finite LCL will overload the modems.","PeriodicalId":397061,"journal":{"name":"2007 18th International Zurich Symposium on Electromagnetic Compatibility","volume":"278 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 18th International Zurich Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCZUR.2007.4388301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

For conducted immunity testing, the injection of the test common mode signal is achieved by way of the couplingdecoupling network (CDN) whose symmetry is not defined in the standards. Due to the low symmetry of PLC cabling, part of the injected common mode test signal is converted into a differential mode signal that interferes with the wanted signal at the input of the modem being tested. We show in this paper that the expected bit error rates due to the differential mode current from the CDN are of the order of 1×10−5 to 5×10−5, which can be handled by coding and MAC ARQ procedures. We also show that it is unlikely that the differential mode signals from the CDN#2019;s finite LCL will overload the modems.
耦合解耦网络对称性对PLC调制解调器传导抗扰度测试的影响
对于传导抗扰度测试,测试共模信号的注入是通过标准中没有定义对称性的耦合去耦网络(CDN)来实现的。由于PLC布线的低对称性,部分注入的共模测试信号被转换成差模信号,从而干扰被测调制解调器输入端的所需信号。我们在本文中表明,由于来自CDN的差分模式电流的预期误码率为1×10−5至5×10−5的顺序,这可以通过编码和MAC ARQ程序来处理。我们还表明,来自CDN#2019的有限LCL的差模信号不太可能使调制解调器过载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信