{"title":"The calculation method of the inductance for three-phase air reactors","authors":"Zheng Liping, Yang Botao","doi":"10.1109/mape.2017.8250891","DOIUrl":null,"url":null,"abstract":"For the design of air core reactors, the inductance calculation is an important technical parameter. Because air core reactors usually work in the three-phase condition, in this paper, the calculation method of the inductance of three-phase air reactors is obtained by using the method of equal division. Firstly, the magnetic flux, the induced potential and the self inductance and mutual inductance of the single-phase air reactor can be calculated accurately by using the method of equal division, Then, the division of different methods was taken according to the structure characteristics of three-phase reactors, and the calculation method of the mutual inductance between coils can be worked out for the three-phase air reactor in the different arrangements. This method is high accurate, simple and practical. The calculation example was given.","PeriodicalId":320947,"journal":{"name":"2017 7th IEEE International Symposium on Microwave, Antenna, Propagation, and EMC Technologies (MAPE)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 7th IEEE International Symposium on Microwave, Antenna, Propagation, and EMC Technologies (MAPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/mape.2017.8250891","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
For the design of air core reactors, the inductance calculation is an important technical parameter. Because air core reactors usually work in the three-phase condition, in this paper, the calculation method of the inductance of three-phase air reactors is obtained by using the method of equal division. Firstly, the magnetic flux, the induced potential and the self inductance and mutual inductance of the single-phase air reactor can be calculated accurately by using the method of equal division, Then, the division of different methods was taken according to the structure characteristics of three-phase reactors, and the calculation method of the mutual inductance between coils can be worked out for the three-phase air reactor in the different arrangements. This method is high accurate, simple and practical. The calculation example was given.