Design and Implementation of Monitor Tester for Validation of ECG Signals

V. Kasik, M. Penhaker, J. Kubícek, M. Cerný, M. Augustynek, David Oczka, Alice Krestanova
{"title":"Design and Implementation of Monitor Tester for Validation of ECG Signals","authors":"V. Kasik, M. Penhaker, J. Kubícek, M. Cerný, M. Augustynek, David Oczka, Alice Krestanova","doi":"10.5220/0007248001270133","DOIUrl":null,"url":null,"abstract":"The paper deals with a design and consequent realization of a monitor tester for validation of the ECG devices, and patient’s monitors for the ECG measurement. In the paper, we describe the electrical design of the plug-in module, which is intended for a transmission of the digital data from the computer. Data are sent by using the controlling SW connected to the parallel port in the plug-in module. An essential part of the proposed module is the three-channel 12 bit D/A converter AD 7398. This converter is able to simultaneously send data from all the three outputs. The converter output is unipolar in the volts units. For this reason, the transmitted signals are adjusted by using the differential amplifiers in order to convert them to the bipolar. The signal’s amplitudes are decreased to the millivolts level by using the voltage dividers. On the base of this solution, the Einthoven ECG leads may be detected.","PeriodicalId":357085,"journal":{"name":"International Conference on Biomedical Electronics and Devices","volume":"144 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Biomedical Electronics and Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5220/0007248001270133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The paper deals with a design and consequent realization of a monitor tester for validation of the ECG devices, and patient’s monitors for the ECG measurement. In the paper, we describe the electrical design of the plug-in module, which is intended for a transmission of the digital data from the computer. Data are sent by using the controlling SW connected to the parallel port in the plug-in module. An essential part of the proposed module is the three-channel 12 bit D/A converter AD 7398. This converter is able to simultaneously send data from all the three outputs. The converter output is unipolar in the volts units. For this reason, the transmitted signals are adjusted by using the differential amplifiers in order to convert them to the bipolar. The signal’s amplitudes are decreased to the millivolts level by using the voltage dividers. On the base of this solution, the Einthoven ECG leads may be detected.
心电信号验证监测仪的设计与实现
本文介绍了一种用于心电设备验证的监护测试仪和用于心电测量的病人监护仪的设计和实现。在本文中,我们描述了用于从计算机传输数字数据的插件模块的电气设计。通过连接到插件模块并口的控制软件发送数据。该模块的一个重要组成部分是三通道12位D/A转换器ad7398。该转换器能够同时从所有三个输出发送数据。转换器输出以伏特为单位为单极。因此,使用差分放大器对传输信号进行调整,以便将其转换为双极信号。通过使用分压器,信号的振幅降低到毫伏级。在此溶液的基础上,可以检测到爱因斯坦心电图导联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信