Relevance between the oro-nasal thermistor signal's derivative and the nasal pressure transducer signal in airflow monitoring

Lala Li, Jia Yan, Jiuxing Liang, Lin Sun, Yu-xi Luo
{"title":"Relevance between the oro-nasal thermistor signal's derivative and the nasal pressure transducer signal in airflow monitoring","authors":"Lala Li, Jia Yan, Jiuxing Liang, Lin Sun, Yu-xi Luo","doi":"10.1109/INEC.2016.7589373","DOIUrl":null,"url":null,"abstract":"Signals of an oro-nasal thermistor (Th) and a nasal air pressure transducer (NP) are widely used as surrogates of airflow for diagnosing sleep-disordered breathing, while the relationships between Th and NP were less discussed. To demonstrate the time derivative of Th is linear correlated with NP, a total of 15,053 epochs (defined 30-s as 1 epoch) clinical data were studied. The correlation coefficients between the time derivative of Th and NP in each epoch were calculated and its mean value is 0.87. It indicated that the time derivative of Th has a linear positive correlation with NP.","PeriodicalId":416565,"journal":{"name":"2016 IEEE International Nanoelectronics Conference (INEC)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Nanoelectronics Conference (INEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INEC.2016.7589373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Signals of an oro-nasal thermistor (Th) and a nasal air pressure transducer (NP) are widely used as surrogates of airflow for diagnosing sleep-disordered breathing, while the relationships between Th and NP were less discussed. To demonstrate the time derivative of Th is linear correlated with NP, a total of 15,053 epochs (defined 30-s as 1 epoch) clinical data were studied. The correlation coefficients between the time derivative of Th and NP in each epoch were calculated and its mean value is 0.87. It indicated that the time derivative of Th has a linear positive correlation with NP.
气流监测中口鼻热敏电阻信号导数与鼻压力传感器信号的相关性
口腔-鼻腔热敏电阻(Th)和鼻腔气压传感器(NP)的信号被广泛用作诊断睡眠呼吸障碍的气流替代品,而Th和NP之间的关系却很少被讨论。为了证明Th的时间导数与NP线性相关,共研究了15053个epoch(定义30-s为1 epoch)的临床数据。计算各历元Th与NP的时间导数的相关系数,其平均值为0.87。结果表明,Th的时间导数与NP呈线性正相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信