{"title":"Voltage feed-forward performance in stationary reference frame controllers for wind power applications","authors":"L. Ma, A. Luna, J. Rocabert, R. Muñoz, F. Córcoles, P. Rodríguez","doi":"10.1109/POWERENG.2011.6036416","DOIUrl":null,"url":null,"abstract":"In order to improve the connected current and the response speed of the controller, stationary reference frame control strategy with proportional resonant (P-R) controller due to its high dynamic and good harmonic compensation performance characteristics was already used in many different DG applications. This paper introduced an additional stationary reference frame control strategies with voltage feed-forward method. By using this method, both the quality of grid connected current and the dynamic performance are improved, which also validated by experiments.","PeriodicalId":166144,"journal":{"name":"2011 International Conference on Power Engineering, Energy and Electrical Drives","volume":"417 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2011.6036416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

In order to improve the connected current and the response speed of the controller, stationary reference frame control strategy with proportional resonant (P-R) controller due to its high dynamic and good harmonic compensation performance characteristics was already used in many different DG applications. This paper introduced an additional stationary reference frame control strategies with voltage feed-forward method. By using this method, both the quality of grid connected current and the dynamic performance are improved, which also validated by experiments.
风力发电用固定参考系控制器的电压前馈性能
为了提高连接电流和控制器的响应速度,比例谐振(P-R)控制器的静止参考框架控制策略由于其高动态和良好的谐波补偿特性,已经在许多不同的DG应用中得到了应用。本文介绍了一种附加的电压前馈静止参考系控制策略。采用该方法既提高了并网电流的质量,又提高了系统的动态性能,并通过实验验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信