G. Di Domenico, G. Zavattini, E. Moretti, A. Piffanelli, M. Giganti, A. Motta, N. Sabba, L. Uccelli, E. Benini, A. Duatti, C. Bolzati, A. Boschi, A. Del Guerra
{"title":"Quantitative YAP-(S)PET small animal scanner: preliminary results","authors":"G. Di Domenico, G. Zavattini, E. Moretti, A. Piffanelli, M. Giganti, A. Motta, N. Sabba, L. Uccelli, E. Benini, A. Duatti, C. Bolzati, A. Boschi, A. Del Guerra","doi":"10.1109/NSSMIC.2001.1008639","DOIUrl":null,"url":null,"abstract":"We have successfully built and characterized small animal PET scanner based on 4 rotating planar detector heads. Each detector module is composed of a matrix of 400 YAP:Ce finger crystals (2/spl times/2/spl times/30 mm/sup 3/ each) directly coupled to position sensitive photomultipliers (Hamamatsu R2486-06). By applying two high resolution collimators to two opposite detectors we realised an integrated PET-SPECT scanner for small animals. At present, at the Department of Experimental and Clinical Medicine of the University of Ferrara, the scanner is employed in small animal SPECT studies with /sup 99m/Tc labeled radiotracers dedicated to obtain quantitative activity measurement in region of interest (ROI) directly from a reconstructed image of a in-vivo rat, with respect to the traditional ex-vivo measurement of activity with gamma counters. To achieve this goal, the scanner was calibrated referring it to a Isodose dose calibrator based on Geiger-Muller counters which previously underwent an absolute calibration with a known activity source. Preliminary results on quantitative tomographic heart perfusion and planar heart biokinetics studies are reported.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"352 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008639","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
We have successfully built and characterized small animal PET scanner based on 4 rotating planar detector heads. Each detector module is composed of a matrix of 400 YAP:Ce finger crystals (2/spl times/2/spl times/30 mm/sup 3/ each) directly coupled to position sensitive photomultipliers (Hamamatsu R2486-06). By applying two high resolution collimators to two opposite detectors we realised an integrated PET-SPECT scanner for small animals. At present, at the Department of Experimental and Clinical Medicine of the University of Ferrara, the scanner is employed in small animal SPECT studies with /sup 99m/Tc labeled radiotracers dedicated to obtain quantitative activity measurement in region of interest (ROI) directly from a reconstructed image of a in-vivo rat, with respect to the traditional ex-vivo measurement of activity with gamma counters. To achieve this goal, the scanner was calibrated referring it to a Isodose dose calibrator based on Geiger-Muller counters which previously underwent an absolute calibration with a known activity source. Preliminary results on quantitative tomographic heart perfusion and planar heart biokinetics studies are reported.