{"title":"A novel digital non-electrical protection for power transformer based on internal pressure characteristics","authors":"C. Yan, Baohui Zhang, Z. Hao, Song Zhang","doi":"10.1109/PESGM.2016.7741793","DOIUrl":null,"url":null,"abstract":"Power transformers play a very critical role in electrical energy transmission. Abnormal performance of transformers would seriously affect the reliability and stability of power system. Non-electrical gas relays are usually used as a main protection of power transformers. Indeed, due to the inherent defects, the gas relay misjudgments happen every year across the world. Given this background, this paper employs a theoretical model and its simulation method to study the relationship between electrical faults and non-electrical pressure variations inside the tank. Based on the essence difference of the pressure characteristics among the internal faults, external faults and normal running condition, a novel transformer protection principle is proposed. Numerical test has indicated that the proposed protection is able to reliably clear the transformer internal faults, even the single-turn fault or other weak faults.","PeriodicalId":155315,"journal":{"name":"2016 IEEE Power and Energy Society General Meeting (PESGM)","volume":"47 11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Power and Energy Society General Meeting (PESGM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2016.7741793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Power transformers play a very critical role in electrical energy transmission. Abnormal performance of transformers would seriously affect the reliability and stability of power system. Non-electrical gas relays are usually used as a main protection of power transformers. Indeed, due to the inherent defects, the gas relay misjudgments happen every year across the world. Given this background, this paper employs a theoretical model and its simulation method to study the relationship between electrical faults and non-electrical pressure variations inside the tank. Based on the essence difference of the pressure characteristics among the internal faults, external faults and normal running condition, a novel transformer protection principle is proposed. Numerical test has indicated that the proposed protection is able to reliably clear the transformer internal faults, even the single-turn fault or other weak faults.