{"title":"Optimal sizing of fixed capacitor banks placed on a distorted interconnected distribution networks by Genetic Algorithms","authors":"A. G. Sayed, H. Youssef","doi":"10.1109/SIBIRCON.2008.4602621","DOIUrl":null,"url":null,"abstract":"In this paper, the optimal sizing of fixed capacitor banks problem in a distorted interconnected distribution system is formulated and solved by a genetic algorithm (GA) solution technique to minimize the cost of power production and capacitor banks under the constraints include voltage limits , sizes of installed capacitors and total harmonic distortion (THD), the algorithm is applied on IEEE 30-bus test system and the results are given for different cases: light and heavy harmonic cases. Computer simulation shows that the harmonic components affect the optimal capacitor sizing.","PeriodicalId":295946,"journal":{"name":"2008 IEEE Region 8 International Conference on Computational Technologies in Electrical and Electronics Engineering","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE Region 8 International Conference on Computational Technologies in Electrical and Electronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIBIRCON.2008.4602621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

In this paper, the optimal sizing of fixed capacitor banks problem in a distorted interconnected distribution system is formulated and solved by a genetic algorithm (GA) solution technique to minimize the cost of power production and capacitor banks under the constraints include voltage limits , sizes of installed capacitors and total harmonic distortion (THD), the algorithm is applied on IEEE 30-bus test system and the results are given for different cases: light and heavy harmonic cases. Computer simulation shows that the harmonic components affect the optimal capacitor sizing.
基于遗传算法的扭曲互联配电网固定电容器组尺寸优化
在电压限值、安装电容器尺寸和总谐波失真(THD)等约束条件下,以发电成本和电容器组成本最小为目标,提出了扭曲互联配电系统中固定电容器组最优尺寸问题,并采用遗传算法求解了该问题,将该算法应用于IEEE 30总线测试系统,给出了轻谐波和重谐波情况下的结果。计算机仿真表明,谐波分量会影响电容器的最佳尺寸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信