{"title":"Influence of External Cables on EM Exposure Investigated with a Human Model in a 3T MRI Coil","authors":"M. Kozlov, N. Weiskopf, H. Möller","doi":"10.1109/USNC-URSI.2019.8861743","DOIUrl":null,"url":null,"abstract":"We evaluated the influence of a commercial clip-on magnetic field camera with 16 field probes on electromagnetic exposure employing a human model located in a realistic 3T MRI whole body radio frequency (RF) coil. The camera setup had a relevant impact on the electric and magnetic field distribution. Variety of generated electric field depended on usage of RF cable traps.","PeriodicalId":383603,"journal":{"name":"2019 USNC-URSI Radio Science Meeting (Joint with AP-S Symposium)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 USNC-URSI Radio Science Meeting (Joint with AP-S Symposium)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/USNC-URSI.2019.8861743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We evaluated the influence of a commercial clip-on magnetic field camera with 16 field probes on electromagnetic exposure employing a human model located in a realistic 3T MRI whole body radio frequency (RF) coil. The camera setup had a relevant impact on the electric and magnetic field distribution. Variety of generated electric field depended on usage of RF cable traps.