Metrological characterization and signal processing of a wearable sensor for the measurement of heart rate variability

N. Morresi, S. Casaccia, G. M. Revel
{"title":"Metrological characterization and signal processing of a wearable sensor for the measurement of heart rate variability","authors":"N. Morresi, S. Casaccia, G. M. Revel","doi":"10.1109/MeMeA52024.2021.9478713","DOIUrl":null,"url":null,"abstract":"This paper presents a methodology for the processing of the Photoplethysmography (PPG) signal measured using a smartwatch during motion tests. For statistical validation, signals from 15 healthy subjects have been collected while the subjects are walking on a treadmill. The motion artifacts (MAs) of the PPG signal have been removed demonstrating that the 37% of the signals are affected by MAs. Then, the experimental performance assessment of the PPG signal, from which the heart rate variability (HRV) has been extracted, by measuring the RR intervals, is compared to the RR intervals extracted from ECG signals measured using a multi-parametric chest belt that is considered as a reference sensor. The uncertainty of the PPG sensor in the measurement of the RR intervals is ± 169 ms, (with a coverage factor k = 2) if compared to the reference method, which in percentage is 30%.","PeriodicalId":429222,"journal":{"name":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"152 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA52024.2021.9478713","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper presents a methodology for the processing of the Photoplethysmography (PPG) signal measured using a smartwatch during motion tests. For statistical validation, signals from 15 healthy subjects have been collected while the subjects are walking on a treadmill. The motion artifacts (MAs) of the PPG signal have been removed demonstrating that the 37% of the signals are affected by MAs. Then, the experimental performance assessment of the PPG signal, from which the heart rate variability (HRV) has been extracted, by measuring the RR intervals, is compared to the RR intervals extracted from ECG signals measured using a multi-parametric chest belt that is considered as a reference sensor. The uncertainty of the PPG sensor in the measurement of the RR intervals is ± 169 ms, (with a coverage factor k = 2) if compared to the reference method, which in percentage is 30%.
用于测量心率变异性的可穿戴传感器的计量特性和信号处理
本文提出了一种处理在运动测试中使用智能手表测量的光电体积脉搏波(PPG)信号的方法。为了统计验证,收集了15名健康受试者在跑步机上行走时的信号。PPG信号的运动伪影(MAs)被去除,表明37%的信号受到MAs的影响。然后,通过测量RR区间对提取心率变异性(HRV)的PPG信号进行实验性能评估,并将其与使用多参数胸带作为参考传感器从心电信号中提取的RR区间进行比较。与参考方法(占30%)相比,PPG传感器测量RR区间的不确定度为±169 ms(覆盖系数k = 2)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信