Effect of Degassing Time on Initiation of Electrical Tree in XLPE

J. He, J. Fang, F. Yang, M. Zhang
{"title":"Effect of Degassing Time on Initiation of Electrical Tree in XLPE","authors":"J. He, J. Fang, F. Yang, M. Zhang","doi":"10.1109/CEIDP55452.2022.9985302","DOIUrl":null,"url":null,"abstract":"Polar crosslinking by-products are prone to be produced in the process of preparing crosslinked polyethylene (XLPE) by peroxide crosslinking method. These cross-linking byproducts remain in the dielectric, which is easy to cause electric field distortion. The electrical tree will be caused at the electric field distortion, it tends to degrade or even breakdown the cable insulation. Therefore, it is necessary to explore the changes of the varieties and contents of crosslinking by-products in the degassing process of XLPE, so as to study the effect of degassing process on the initiation of electrical tree in XLPE. XLPE sheet samples were prepared by hot pressing method. Samples degassed for 0d, 2d, 4d and 6d were obtained in a vacuum drying oven at 70°C. Initiation of electrical tree experiments were carried out on four groups of samples. The varieties and contents of crosslinking by-products were characterized by gas chromatography-mass spectrometry (GC-MS), and the effects of crosslinking by-products on the initiation of electrical tree with different degassing time were studied. The results show that under the set degassing conditions, the sample degassed for 2 days has the highest electrical tree initiation voltage. Compared with degassed 0d, the sample degassed 2d has less pores and relatively dense structure. Compared with degassing for 4d and 6d, the content of acetophenone in degassing for 2 days is higher, and acetophenone as a voltage stabilizer has a good inhibitory effect on electrical tree.","PeriodicalId":374945,"journal":{"name":"2022 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP55452.2022.9985302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Polar crosslinking by-products are prone to be produced in the process of preparing crosslinked polyethylene (XLPE) by peroxide crosslinking method. These cross-linking byproducts remain in the dielectric, which is easy to cause electric field distortion. The electrical tree will be caused at the electric field distortion, it tends to degrade or even breakdown the cable insulation. Therefore, it is necessary to explore the changes of the varieties and contents of crosslinking by-products in the degassing process of XLPE, so as to study the effect of degassing process on the initiation of electrical tree in XLPE. XLPE sheet samples were prepared by hot pressing method. Samples degassed for 0d, 2d, 4d and 6d were obtained in a vacuum drying oven at 70°C. Initiation of electrical tree experiments were carried out on four groups of samples. The varieties and contents of crosslinking by-products were characterized by gas chromatography-mass spectrometry (GC-MS), and the effects of crosslinking by-products on the initiation of electrical tree with different degassing time were studied. The results show that under the set degassing conditions, the sample degassed for 2 days has the highest electrical tree initiation voltage. Compared with degassed 0d, the sample degassed 2d has less pores and relatively dense structure. Compared with degassing for 4d and 6d, the content of acetophenone in degassing for 2 days is higher, and acetophenone as a voltage stabilizer has a good inhibitory effect on electrical tree.
脱气时间对交联聚乙烯电树萌生的影响
过氧化交联法制备交联聚乙烯(XLPE)过程中容易产生极性交联副产物。这些交联副产物留在电介质中,容易引起电场畸变。电树在电场作用下会引起变形,容易使电缆绝缘劣化甚至击穿。因此,有必要探索XLPE脱气过程中交联副产物的种类和含量的变化,以研究脱气过程对XLPE中电树萌生的影响。采用热压法制备了XLPE板材样品。在70°C的真空干燥箱中脱气0d、2d、4d和6d的样品。对四组样品进行了初始电树实验。采用气相色谱-质谱联用技术(GC-MS)对交联副产物的种类和含量进行了表征,并研究了不同脱气时间交联副产物对电树起始的影响。结果表明:在设定的脱气条件下,脱气2天的样品电气树起始电压最高;与脱气0d相比,脱气2d样品孔隙较少,结构相对致密。与脱气4d和6d相比,脱气2d的苯乙酮含量较高,苯乙酮作为稳压器对电树有较好的抑制作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信