{"title":"Protection and common mode voltage of The Push-Pull Partial Power Converter","authors":"O. Abdel-Rahim, A. Chub, A. Blinov, D. Vinnikov","doi":"10.1109/CPERE56564.2023.10119636","DOIUrl":null,"url":null,"abstract":"This work studies the operation of Series partial power converter (S-PPC) based on the push-pull configuration at abnormal conditions. Protection devices are mandatory in PPC system design to avoid overdesigning process to eliminate the effect of abnormal transient modes. By adding simple protection devices, system size and cost to be maintained at minimum. A solid state circuit breaker is implemented for protection purposes. Leakage current, common mode voltage and operation at different fault conditions are studied in this work","PeriodicalId":169048,"journal":{"name":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPERE56564.2023.10119636","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work studies the operation of Series partial power converter (S-PPC) based on the push-pull configuration at abnormal conditions. Protection devices are mandatory in PPC system design to avoid overdesigning process to eliminate the effect of abnormal transient modes. By adding simple protection devices, system size and cost to be maintained at minimum. A solid state circuit breaker is implemented for protection purposes. Leakage current, common mode voltage and operation at different fault conditions are studied in this work
推挽式部分功率变换器的保护及共模电压
本文研究了基于推挽结构的串联部分功率变换器(S-PPC)在异常工况下的运行情况。保护装置在PPC系统设计中是强制性的,以避免过度设计过程中消除异常瞬态模式的影响。通过添加简单的保护装置,将系统的尺寸和维护成本降至最低。一种固态断路器用于保护目的。研究了泄漏电流、共模电压和不同故障条件下的运行情况
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信