Investigation of transient processes of overvoltages in transformer neutral

U. Ilioitiene, A. Rožanskienė, D. Sakauskaite, Vidmantas Ticka Kaunas
{"title":"Investigation of transient processes of overvoltages in transformer neutral","authors":"U. Ilioitiene, A. Rožanskienė, D. Sakauskaite, Vidmantas Ticka Kaunas","doi":"10.1109/POWERENG.2015.7266320","DOIUrl":null,"url":null,"abstract":"Neutral of major part of power transformers in electrical energy system with effectively earthed neutral is isolated. Isolated neutral is protected by valve-type arresters or lately by surge arresters. As a result travelling wave of lightning discharge to the line electromagnetic impulse is coming to transformer causing overvoltages in transformer neutral. If protective characteristics of surge arrester are improperly coordinated with insulation then insulation is broken in the area of neutral. This paper analyses character of transient processes and operating conditions of surge arresters in switchgear and it's influence to insulation of transformer.","PeriodicalId":334135,"journal":{"name":"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)","volume":"200 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2015.7266320","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Neutral of major part of power transformers in electrical energy system with effectively earthed neutral is isolated. Isolated neutral is protected by valve-type arresters or lately by surge arresters. As a result travelling wave of lightning discharge to the line electromagnetic impulse is coming to transformer causing overvoltages in transformer neutral. If protective characteristics of surge arrester are improperly coordinated with insulation then insulation is broken in the area of neutral. This paper analyses character of transient processes and operating conditions of surge arresters in switchgear and it's influence to insulation of transformer.
变压器中性点过电压暂态过程的研究
在中性点有效接地的电力系统中,大部分电力变压器的中性点是隔离的。隔离中性点由阀式避雷器保护,最近又用避雷器保护。雷电放电对线路电磁脉冲的行波进入变压器,造成变压器中性点过电压。如果避雷器的保护特性与绝缘不适当协调,则中性点区域的绝缘就会断裂。分析了开关柜避雷器的暂态过程和工作状态的特点及其对变压器绝缘的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信