{"title":"Philosophy of Protection for The Macagua-Callao-Claritas 400 kV Line","authors":"H. Pineda, J. L. Flores","doi":"10.1109/TDCLA.2006.311570","DOIUrl":null,"url":null,"abstract":"In order to protect in case of fault on the Macagua-Callao-Claritas 400 kV line that supply energy to Eletronorte utilities in Brazil, a particular protection scheme was designed under a fault detection table, which allowed to evaluate the different scenarios in case of the internal and external fault. This scheme are made up of relays of distance and directional overcurrent in the three substations (Macagua-Callao-Claritas), operating in a special permissive overreach scheme with weak infeed, using an optical fiber connection as communication way between each terminal for teleprotection equipments to send and receive the necessary permissive signals to active the scheme. Additionally, for transient faults, the scheme has a single phase auto reclosing which increases the continuity of service of our customer Eletronorte in Brazil","PeriodicalId":406067,"journal":{"name":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDCLA.2006.311570","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In order to protect in case of fault on the Macagua-Callao-Claritas 400 kV line that supply energy to Eletronorte utilities in Brazil, a particular protection scheme was designed under a fault detection table, which allowed to evaluate the different scenarios in case of the internal and external fault. This scheme are made up of relays of distance and directional overcurrent in the three substations (Macagua-Callao-Claritas), operating in a special permissive overreach scheme with weak infeed, using an optical fiber connection as communication way between each terminal for teleprotection equipments to send and receive the necessary permissive signals to active the scheme. Additionally, for transient faults, the scheme has a single phase auto reclosing which increases the continuity of service of our customer Eletronorte in Brazil