Bacterial and Chemical Contamination Associated Carpet Dust in the Holy Mosque, Makkah Al-Mukarramah

B. Mashat
{"title":"Bacterial and Chemical Contamination Associated Carpet Dust in the Holy Mosque, Makkah Al-Mukarramah","authors":"B. Mashat","doi":"10.4197/met.26-2.9","DOIUrl":null,"url":null,"abstract":"Carpets are widely used as surface covering in the holy mosque (Almasjed Alharam) settings, and they are prone to contamination with infectious agents and chemical components. This study aims to evaluate the concentrations of bacteria and chemical pollutants associated carpet dust in the holy mosque, as well as bacterial concentrations in the air state. The dust samples were collected from eighty carpets during month of Ramadan 2011, using a cord portable vacuum cleaner. Airborne bacteria were collected using Airport MD8 gelatin filter sampler. Bacterial concentrations varied depending on location of carpets inside the mosque, with no significant differences between locations (P≥0.05). The highest mean bacterial concentrations associated dust (256.42x10 CFU/m) and in the air state (1.12x10 CFU/m) were found at the ground floor of 1st expansion location. The highest re-suspension factor (RF) was found at the ground floor of 1st expansion, and the lowest at ground floor of 2nd expansion. Bacillus (25%), Pseudomonas (13%) and Micrococcus (12%) were the dominated bacterial genera. Chloride and ammonium concentrations associated dust were higher at the basement and the ground floor locations. The results did not indicate the presence of any apparent seriousness of the current situation of the carpets in the holy mosque. The data can be treated as a first step in determining the acceptable levels for microorganisms associated carpets in the common indoor environments.","PeriodicalId":254766,"journal":{"name":"Journal of King Abdulaziz University-meteorology, Environment and Arid Land Agriculture Sciences","volume":"184 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of King Abdulaziz University-meteorology, Environment and Arid Land Agriculture Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4197/met.26-2.9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Carpets are widely used as surface covering in the holy mosque (Almasjed Alharam) settings, and they are prone to contamination with infectious agents and chemical components. This study aims to evaluate the concentrations of bacteria and chemical pollutants associated carpet dust in the holy mosque, as well as bacterial concentrations in the air state. The dust samples were collected from eighty carpets during month of Ramadan 2011, using a cord portable vacuum cleaner. Airborne bacteria were collected using Airport MD8 gelatin filter sampler. Bacterial concentrations varied depending on location of carpets inside the mosque, with no significant differences between locations (P≥0.05). The highest mean bacterial concentrations associated dust (256.42x10 CFU/m) and in the air state (1.12x10 CFU/m) were found at the ground floor of 1st expansion location. The highest re-suspension factor (RF) was found at the ground floor of 1st expansion, and the lowest at ground floor of 2nd expansion. Bacillus (25%), Pseudomonas (13%) and Micrococcus (12%) were the dominated bacterial genera. Chloride and ammonium concentrations associated dust were higher at the basement and the ground floor locations. The results did not indicate the presence of any apparent seriousness of the current situation of the carpets in the holy mosque. The data can be treated as a first step in determining the acceptable levels for microorganisms associated carpets in the common indoor environments.
麦加穆卡拉玛圣清真寺地毯灰尘中的细菌和化学污染
地毯被广泛用作神圣清真寺(Almasjed Alharam)设置的表面覆盖物,它们容易受到传染性病原体和化学成分的污染。本研究旨在评估神圣清真寺地毯粉尘中细菌和化学污染物的浓度,以及空气状态中的细菌浓度。这些灰尘样本是在2011年斋月期间用便携式真空吸尘器从80块地毯上收集的。空气细菌采集采用Airport MD8明胶过滤采样器。细菌浓度随清真寺内地毯位置的不同而变化,不同地点之间无显著差异(P≥0.05)。在1号膨胀位置的底层,发现了最高的平均细菌浓度(256.42 × 10 CFU/m)和空气状态(1.12 × 10 CFU/m)。再悬浮系数(RF)在第1层扩展层最高,在第2层扩展层最低。芽孢杆菌(25%)、假单胞菌(13%)和微球菌(12%)为优势菌属。与粉尘相关的氯化物和铵的浓度在地下室和一楼较高。调查结果并没有显示出清真寺内地毯目前的情况有任何明显的严重性。这些数据可以作为确定普通室内环境中与地毯有关的微生物可接受水平的第一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信