Online PD Measurement by Detecting the Pulsed Compensating Current in High Voltage Equipment

Chissanupong Srinangyam, P. Pannil, P. Nimsanong, C. Chuayin, K. Thungsook, N. Pattanadech
{"title":"Online PD Measurement by Detecting the Pulsed Compensating Current in High Voltage Equipment","authors":"Chissanupong Srinangyam, P. Pannil, P. Nimsanong, C. Chuayin, K. Thungsook, N. Pattanadech","doi":"10.1109/iceast55249.2022.9826301","DOIUrl":null,"url":null,"abstract":"This paper discusses the pulsed compensating current caused by partial discharge (PD) phenomena that flows inside the electrical equipment installed in the power system. Such electrical equipment like to be the capacitive coupler in the partial discharge test circuit. In order to study the pulsed compensating current of the PD measurement, artificial PD source such as corona, surface, and internal was used in this experiment. The electrical equipment like surge arrester combined with HFCT sensor utilized to detect the PD pulse current. Furthermore, this proposed technique has been applied for online PD measurement in substations. It was found that the surge arrester could compensate for the pulse current arising from the PD source. This study will be helpful information for online PD measurement.","PeriodicalId":441430,"journal":{"name":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 8th International Conference on Engineering, Applied Sciences, and Technology (ICEAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iceast55249.2022.9826301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper discusses the pulsed compensating current caused by partial discharge (PD) phenomena that flows inside the electrical equipment installed in the power system. Such electrical equipment like to be the capacitive coupler in the partial discharge test circuit. In order to study the pulsed compensating current of the PD measurement, artificial PD source such as corona, surface, and internal was used in this experiment. The electrical equipment like surge arrester combined with HFCT sensor utilized to detect the PD pulse current. Furthermore, this proposed technique has been applied for online PD measurement in substations. It was found that the surge arrester could compensate for the pulse current arising from the PD source. This study will be helpful information for online PD measurement.
高压设备中脉冲补偿电流检测的在线PD测量
本文讨论了电力系统中电气设备内部由于局部放电现象而产生的脉冲补偿电流。在局部放电试验电路中,这种电气设备通常用作容性耦合器。为了研究局部放电测量的脉冲补偿电流,本实验采用了电晕源、表面源和内部源等人工局部放电源。利用避雷器等电气设备与HFCT传感器相结合来检测PD脉冲电流。并将该方法应用于变电站的在线PD测量中。结果表明,该避雷器可以补偿PD源产生的脉冲电流。本研究将为在线PD测量提供有益的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信