Development of Intra-Aortic Balloon Pump with Vascular Stent and Vitro Simulation Verification

Yao Xie, Dong Yang, Honglong Yu, Kun Wang, Qilian Xie
{"title":"Development of Intra-Aortic Balloon Pump with Vascular Stent and Vitro Simulation Verification","authors":"Yao Xie, Dong Yang, Honglong Yu, Kun Wang, Qilian Xie","doi":"10.1109/ICBCB52223.2021.9459233","DOIUrl":null,"url":null,"abstract":"Intra-aortic balloon pump (IABP) has been widely used in the rescue and treatment of patients with cardiac insufficiency and heart failure, but IABP is not effective in increasing cardiac output. In this study, an aortic balloon pump with a vascular stent was developed, and an experimental bench for simulating heart failure in vitro was built to study the effect of a balloon pump with a vascular stent on hemodynamic changes. Experiment results have shown that compared with the traditional balloon pump, a balloon pump with a stent has higher cardiac output and counterpulsation pressure, lower systolic and diastolic blood pressure, and therefore has better performance in heart failure treatment.","PeriodicalId":178168,"journal":{"name":"2021 IEEE 9th International Conference on Bioinformatics and Computational Biology (ICBCB)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 9th International Conference on Bioinformatics and Computational Biology (ICBCB)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBCB52223.2021.9459233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Intra-aortic balloon pump (IABP) has been widely used in the rescue and treatment of patients with cardiac insufficiency and heart failure, but IABP is not effective in increasing cardiac output. In this study, an aortic balloon pump with a vascular stent was developed, and an experimental bench for simulating heart failure in vitro was built to study the effect of a balloon pump with a vascular stent on hemodynamic changes. Experiment results have shown that compared with the traditional balloon pump, a balloon pump with a stent has higher cardiac output and counterpulsation pressure, lower systolic and diastolic blood pressure, and therefore has better performance in heart failure treatment.
血管支架主动脉内球囊泵的研制及体外仿真验证
主动脉内球囊泵(IABP)已被广泛应用于心功能不全和心力衰竭患者的抢救和治疗,但IABP在增加心输出量方面效果不明显。本研究研制了带血管支架的主动脉球囊泵,并搭建了体外模拟心力衰竭实验台,研究了带血管支架的球囊泵对血流动力学变化的影响。实验结果表明,与传统的球囊泵相比,支架球囊泵具有更高的心输出量和反搏压,更低的收缩压和舒张压,因此在心力衰竭治疗中具有更好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信