{"title":"High resolution integrated microfluidic Fabry-Perot refractometer in silicon","authors":"Raphael St-Gelais, Jonathan Masson, Yves-Alain Peter","doi":"10.1109/OMEMS.2008.4607806","DOIUrl":null,"url":null,"abstract":"We present a high resolution, robust and low cost integrated refractometer for microfluidic systems. The device is made of two Bragg reflectors vertically etched in silicon to form an in-plane Fabry-Perot filter. Liquids are injected in the cavity through a microfluidic channel and the variation of the refractive index induces a shift of the resonance wavelength. A sensitivity of 920 nm/RIU (refractive index units) and a resolution of less than 10-3 are obtained and are in good agreement with optical simulations. This resolution is, to our knowledge, the lowest ever reported for an integrated microfluidic Fabry-Perot refractometer.","PeriodicalId":402931,"journal":{"name":"2008 IEEE/LEOS International Conference on Optical MEMs and Nanophotonics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE/LEOS International Conference on Optical MEMs and Nanophotonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OMEMS.2008.4607806","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

We present a high resolution, robust and low cost integrated refractometer for microfluidic systems. The device is made of two Bragg reflectors vertically etched in silicon to form an in-plane Fabry-Perot filter. Liquids are injected in the cavity through a microfluidic channel and the variation of the refractive index induces a shift of the resonance wavelength. A sensitivity of 920 nm/RIU (refractive index units) and a resolution of less than 10-3 are obtained and are in good agreement with optical simulations. This resolution is, to our knowledge, the lowest ever reported for an integrated microfluidic Fabry-Perot refractometer.
高分辨率集成硅微流控法布里-珀罗折光计
我们提出了一种用于微流体系统的高分辨率、鲁棒性和低成本的集成折射计。该装置由两个垂直蚀刻在硅上的布拉格反射器组成,形成一个平面内的法布里-珀罗滤波器。液体通过微流体通道注入腔内,折射率的变化引起共振波长的移位。获得了920 nm/RIU(折射率单位)的灵敏度和小于10-3的分辨率,与光学模拟结果吻合较好。据我们所知,这是迄今为止报道的集成微流体法布里-珀罗折射仪的最低分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信