Tuning the narrow-band beam position monitor sampling clock to remove the aliasing errors in APS storage ring orbit measurements

X. Sun, O. Singh
{"title":"Tuning the narrow-band beam position monitor sampling clock to remove the aliasing errors in APS storage ring orbit measurements","authors":"X. Sun, O. Singh","doi":"10.1109/PAC.2007.4440019","DOIUrl":null,"url":null,"abstract":"The Advanced Photon Source storage ring employs a real-time orbit correction system to reduce orbit motion up to 50 Hz. This system uses up to 142 narrow-band rf beam position monitors (Nbbpms) in a correction algorithm by sampling at a frequency of 1.53 kHz. Several Nbbpms exhibit aliasing errors in orbit measurements, rendering these Nbbpms unusable in real-time orbit feedback. The aliasing errors are caused by beating effects of the internal sampling clocks with various other processing clocks residing within the BPM electronics. A programmable external clock has been employed to move the aliasing errors out of the active frequency band of the real-time feedback system (RTFB) and rms beam motion calculation. This paper discusses the process of tuning and provides test results.","PeriodicalId":446026,"journal":{"name":"2007 IEEE Particle Accelerator Conference (PAC)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Particle Accelerator Conference (PAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.2007.4440019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The Advanced Photon Source storage ring employs a real-time orbit correction system to reduce orbit motion up to 50 Hz. This system uses up to 142 narrow-band rf beam position monitors (Nbbpms) in a correction algorithm by sampling at a frequency of 1.53 kHz. Several Nbbpms exhibit aliasing errors in orbit measurements, rendering these Nbbpms unusable in real-time orbit feedback. The aliasing errors are caused by beating effects of the internal sampling clocks with various other processing clocks residing within the BPM electronics. A programmable external clock has been employed to move the aliasing errors out of the active frequency band of the real-time feedback system (RTFB) and rms beam motion calculation. This paper discusses the process of tuning and provides test results.
对窄带波束位置监测采样时钟进行了调谐,消除了APS存储环轨道测量中的混叠误差
先进光子源存储环采用实时轨道校正系统,将轨道运动降低到50 Hz。该系统使用多达142个窄带射频波束位置监视器(Nbbpms),采用校正算法,采样频率为1.53 kHz。一些Nbbpms在轨道测量中表现出混叠误差,使得这些Nbbpms无法用于实时轨道反馈。混叠误差是由内部采样时钟与BPM电子器件中驻留的各种其他处理时钟的跳动效应引起的。采用可编程外部时钟将混叠误差移出实时反馈系统(RTFB)的有源频带并进行波束运动的均方根计算。本文讨论了调优过程,并给出了测试结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信