Measurements of the Induced Power in a Shape Shifting Transmission Line According to Immunity Tests in Reverberation and Semi Anechoic Chamber

M. Obholz, D. Peier
{"title":"Measurements of the Induced Power in a Shape Shifting Transmission Line According to Immunity Tests in Reverberation and Semi Anechoic Chamber","authors":"M. Obholz, D. Peier","doi":"10.1109/EMCZUR.2009.4783483","DOIUrl":null,"url":null,"abstract":"Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.","PeriodicalId":192851,"journal":{"name":"2009 20th International Zurich Symposium on Electromagnetic Compatibility","volume":"213 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 20th International Zurich Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCZUR.2009.4783483","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Measurements of the induced power in a shape shifting transmission line are performed in the semi anechoic and reverberation chamber. The test setups are according to immunity tests. The device under test is a bar antenna, seen as transmission line, which is investigated for 3 geometric constellations. The differences between the measurement results in both test environments are pointed out. Finally, a maximum hold, over all measurements in the semi anechoic chamber, is compared to one measurement in the reverberation chamber.
利用混响和半消声室抗扰度试验测量变形传输线的感应功率
在半消声和混响室中对变形传输线的感应功率进行了测量。测试设置是根据免疫测试。测试中的装置是一个条形天线,被视为传输线,它被研究了3个几何星座。指出了两种测试环境下测量结果的差异。最后,将半消声室中所有测量值的最大保持量与混响室中的一次测量值进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信