WASTE MATERIALS AS SUBSTRATES IN VERTICAL FLOW CONSTRUCTED WETLANDS TREATING DOMESTIC WASTEWATER

Atif Mustafa, Mehmood Ali
{"title":"WASTE MATERIALS AS SUBSTRATES IN VERTICAL FLOW CONSTRUCTED WETLANDS TREATING DOMESTIC WASTEWATER","authors":"Atif Mustafa, Mehmood Ali","doi":"10.2495/wm180311","DOIUrl":null,"url":null,"abstract":"Vertical flow constructed wetlands (VFCW) are considered to be one of the most efficient type of wetlands and require a lesser footprint in comparison to other wetland types. Substrate is an important component of wetland. We used the common gravel (VFCW 1) and three waste materials: concrete (VFCW 2), slag concrete (VFCW 3) and coconut husk (VFCW 4) as substrates in experimental wetlands. All four experimental wetlands have been constructed in uPVC pipes, diameter and height of each VFCW was 89 mm and 1000 mm, respectively. A 15 mm diameter perforated pipe that penetrates to the wetland bottom was installed in each wetland for passive aeration. Canna indica, an ornamental plant was planted in all four wetlands. Pre-treated wastewater from a wastewater treatment plant was added manually to all VFCW. The maximum plant height observed was 78.7 cm in VFCW 1 while minimum plant height observed was 53.3 cm in VFCW 3. The four VFCW removed all monitored contaminants with good removal efficiencies during the 8 months monitoring period: suspended solids (79%, 74%, 74%, 54%); BOD (54%, 42%, 42%, 2%); COD (54%; 47%; 44%, 34%); ammonia-nitrogen (54%, 46%, 38%, 38%), ortho-phosphate (67%, 61%, 64%, 53%); and fecal coliforms (55%, 40%, 14%, 52%). DO levels increased for VFCW 1 and 4 and nitrate levels increased in all wetlands confirming the nitrification process. For the various waste materials used following were our observations: VFCW 2 performed the best for organic matter and ammonia-nitrogen removal while VFCW 3 outperformed others for phosphorus removal and VFCW 4 had the highest percentage of fecal coliforms removal.","PeriodicalId":103799,"journal":{"name":"Waste Management and the Environment IX","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Waste Management and the Environment IX","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/wm180311","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Vertical flow constructed wetlands (VFCW) are considered to be one of the most efficient type of wetlands and require a lesser footprint in comparison to other wetland types. Substrate is an important component of wetland. We used the common gravel (VFCW 1) and three waste materials: concrete (VFCW 2), slag concrete (VFCW 3) and coconut husk (VFCW 4) as substrates in experimental wetlands. All four experimental wetlands have been constructed in uPVC pipes, diameter and height of each VFCW was 89 mm and 1000 mm, respectively. A 15 mm diameter perforated pipe that penetrates to the wetland bottom was installed in each wetland for passive aeration. Canna indica, an ornamental plant was planted in all four wetlands. Pre-treated wastewater from a wastewater treatment plant was added manually to all VFCW. The maximum plant height observed was 78.7 cm in VFCW 1 while minimum plant height observed was 53.3 cm in VFCW 3. The four VFCW removed all monitored contaminants with good removal efficiencies during the 8 months monitoring period: suspended solids (79%, 74%, 74%, 54%); BOD (54%, 42%, 42%, 2%); COD (54%; 47%; 44%, 34%); ammonia-nitrogen (54%, 46%, 38%, 38%), ortho-phosphate (67%, 61%, 64%, 53%); and fecal coliforms (55%, 40%, 14%, 52%). DO levels increased for VFCW 1 and 4 and nitrate levels increased in all wetlands confirming the nitrification process. For the various waste materials used following were our observations: VFCW 2 performed the best for organic matter and ammonia-nitrogen removal while VFCW 3 outperformed others for phosphorus removal and VFCW 4 had the highest percentage of fecal coliforms removal.
垂直流人工湿地处理生活污水的基质研究
垂直流人工湿地(VFCW)被认为是最有效的湿地类型之一,与其他类型的湿地相比,它需要更少的足迹。基质是湿地的重要组成部分。我们使用普通碎石(VFCW 1)和三种废弃物:混凝土(VFCW 2)、矿渣混凝土(VFCW 3)和椰子壳(VFCW 4)作为实验湿地的基质。4个实验湿地均采用uPVC管道构建,每个VFCW的直径和高度分别为89 mm和1000 mm。每片湿地均安装直径15mm的穿孔管,穿透至湿地底部进行被动曝气。观赏植物美人蕉(美人蕉)在四个湿地均有种植。将来自污水处理厂的预处理废水手动添加到所有VFCW中。vfcw1植株最高78.7 cm, vfcw3植株最低53.3 cm。在8个月的监测期间,4种VFCW对所有监测污染物的去除率均较好:悬浮物(79%、74%、74%、54%);Bod (54%, 42%, 42%, 2%);鳕鱼(54%;47%;44%、34%);氨氮(54%、46%、38%、38%)、正磷酸盐(67%、61%、64%、53%);粪便大肠菌群(55%,40%,14%,52%)。vfcw1和vfcw4的DO水平升高,所有湿地的硝酸盐水平升高,证实了硝化过程。对于不同的废弃物,我们的观察结果如下:VFCW 2对有机物和氨氮的去除效果最好,VFCW 3对磷的去除效果最好,VFCW 4对粪便大肠菌群的去除率最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信