Experience with partial discharge testing during voltage surges as required by IEC 60034-18-41 and 60034-18-42

I. Culbert
{"title":"Experience with partial discharge testing during voltage surges as required by IEC 60034-18-41 and 60034-18-42","authors":"I. Culbert","doi":"10.1109/PAPCON.2009.5185418","DOIUrl":null,"url":null,"abstract":"This paper describes the stator winding insulation aging mechanisms that can be induced by low and medium voltage, voltage source converter drives and how IEC 60034-18-41 and IEC 60034-18-42 can be applied to qualify motor stator windings for use with them. IEC 60034-18-41 is a document that describes the procedures for qualifying the insulation system of low voltage motor stator windings supplied from voltage source converters. This technical specification requires the measurement of partial discharge during short-risetime voltage surges when the test object is a normal motor stator winding. IEC 60034-18-42 deals with procedures for qualifying form-wound, medium voltage stator windings for motors to be fed from voltage source converters. The procedures in this document deal with tests on the various components of the insulation system to be qualified.","PeriodicalId":217420,"journal":{"name":"Conference Record of 2009 Annual Pulp and Paper Industry Technical Conference","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of 2009 Annual Pulp and Paper Industry Technical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAPCON.2009.5185418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper describes the stator winding insulation aging mechanisms that can be induced by low and medium voltage, voltage source converter drives and how IEC 60034-18-41 and IEC 60034-18-42 can be applied to qualify motor stator windings for use with them. IEC 60034-18-41 is a document that describes the procedures for qualifying the insulation system of low voltage motor stator windings supplied from voltage source converters. This technical specification requires the measurement of partial discharge during short-risetime voltage surges when the test object is a normal motor stator winding. IEC 60034-18-42 deals with procedures for qualifying form-wound, medium voltage stator windings for motors to be fed from voltage source converters. The procedures in this document deal with tests on the various components of the insulation system to be qualified.
具有IEC 60034-18-41和60034-18-42要求的电压浪涌时局部放电试验经验
本文介绍了低压和中压、电压源变换器驱动引起的定子绕组绝缘老化机理,以及如何应用IEC 60034-18-41和IEC 60034-18-42标准对电机定子绕组进行鉴定。IEC 60034-18-41描述了电压源变流器提供的低压电机定子绕组绝缘系统的鉴定程序。本技术规范要求在测试对象为普通电机定子绕组时,测量短时电压浪涌时的局部放电。IEC 60034-18-42规定了由电压源变流器馈电的电机用形式绕组、中压定子绕组的鉴定程序。本文件中的程序涉及绝缘系统各部件的合格测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信