National survey on medical exposure to patients undergoing diagnostic radiology examinations: An initial overview on CT doses at UAE hospitals

J. Alsuwaidi, H. Alawadhi, Ali Rahanjam, Mohamad Ahmed El Hallag, J. Janaczek, F. A. Kaabi, W. Al-Shamsi, Mohammad Abu Srour
{"title":"National survey on medical exposure to patients undergoing diagnostic radiology examinations: An initial overview on CT doses at UAE hospitals","authors":"J. Alsuwaidi, H. Alawadhi, Ali Rahanjam, Mohamad Ahmed El Hallag, J. Janaczek, F. A. Kaabi, W. Al-Shamsi, Mohammad Abu Srour","doi":"10.1109/MECBME.2011.5752150","DOIUrl":null,"url":null,"abstract":"The IAEA — UAE Project on Patient Radiation Protection aimed at evaluating radiation dose levels received by patients during radiological examinations. In this paper, we are presenting the preliminary results of patient doses in Computed Tomography (CT) examinations at 4 UAE hospitals (3 major governmental hospitals and 1 private). Five Multi-slice CT (MSCT) systems (4S, 16S and 64S) were included in this study. All these systems are enrolled in quality control program. CT dose levels were evaluated through either thermoluminescent detectors (TLD-100) or by using Head (16-cm Diameter) and Body (32-cm Diameter) cylindrical CTDI PMMA phantom fitted with a 10 cm pencil ionization chamber. Adult and pediatric patient CT doses were collected from common CT examinations of the Head, Chest and Abdomen & Pelvis. The CT Dose Index (CTDIvol), Dose Length Product (DLP) and Effective Doses (E) were the main CT dosimetry parameters evaluated in this project. The CTDIvol results of all CT systems showed acceptable compliance with those reported by professional organizations. The range of 3rd quartile of adult DLP values for CT Head examinations among the 4 hospitals was 384.106–5031.92 mGy.cm. The adult CT Chest examinations demonstrated the range of the 3rd quartile DLP values between 122.035–1423.06 mGy.cm while the Abdomen & Pelvis examinations showed a range of 258.446–1701.135 mGy.cm. Hospitals DD3, AA13 and ANM14 are within the UAE initial adapted local Dose Reference Levels (DRLs) and are comparable to the European guidelines while hospitals TA1 and TA2 are higher. The CT effective doses of almost all the examination types were within the level mentioned by international organizations such as the ICRP (Report 102, 2007) with the exception of CT examinations performed at TA1 & TA2. Further work is developed to reduce patient radiation doses of the common CT examinations of the Head, Chest and Abdomen & Pelvis. Adult and pediatric patient data collection and analysis of CT doses from other hospitals at the UAE are in progress.","PeriodicalId":348448,"journal":{"name":"2011 1st Middle East Conference on Biomedical Engineering","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 1st Middle East Conference on Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECBME.2011.5752150","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The IAEA — UAE Project on Patient Radiation Protection aimed at evaluating radiation dose levels received by patients during radiological examinations. In this paper, we are presenting the preliminary results of patient doses in Computed Tomography (CT) examinations at 4 UAE hospitals (3 major governmental hospitals and 1 private). Five Multi-slice CT (MSCT) systems (4S, 16S and 64S) were included in this study. All these systems are enrolled in quality control program. CT dose levels were evaluated through either thermoluminescent detectors (TLD-100) or by using Head (16-cm Diameter) and Body (32-cm Diameter) cylindrical CTDI PMMA phantom fitted with a 10 cm pencil ionization chamber. Adult and pediatric patient CT doses were collected from common CT examinations of the Head, Chest and Abdomen & Pelvis. The CT Dose Index (CTDIvol), Dose Length Product (DLP) and Effective Doses (E) were the main CT dosimetry parameters evaluated in this project. The CTDIvol results of all CT systems showed acceptable compliance with those reported by professional organizations. The range of 3rd quartile of adult DLP values for CT Head examinations among the 4 hospitals was 384.106–5031.92 mGy.cm. The adult CT Chest examinations demonstrated the range of the 3rd quartile DLP values between 122.035–1423.06 mGy.cm while the Abdomen & Pelvis examinations showed a range of 258.446–1701.135 mGy.cm. Hospitals DD3, AA13 and ANM14 are within the UAE initial adapted local Dose Reference Levels (DRLs) and are comparable to the European guidelines while hospitals TA1 and TA2 are higher. The CT effective doses of almost all the examination types were within the level mentioned by international organizations such as the ICRP (Report 102, 2007) with the exception of CT examinations performed at TA1 & TA2. Further work is developed to reduce patient radiation doses of the common CT examinations of the Head, Chest and Abdomen & Pelvis. Adult and pediatric patient data collection and analysis of CT doses from other hospitals at the UAE are in progress.
对接受诊断性放射学检查的患者进行医疗照射的全国调查:对阿联酋医院CT剂量的初步概述
原子能机构-阿联酋病人辐射防护项目旨在评估病人在放射检查期间接受的辐射剂量水平。在本文中,我们介绍了4家阿联酋医院(3家主要的政府医院和1家私立医院)在计算机断层扫描(CT)检查中患者剂量的初步结果。本研究包括5套多层CT (MSCT)系统(4S、16S和64S)。所有这些系统都参加了质量控制计划。CT剂量水平通过热释光检测器(TLD-100)或头部(直径16厘米)和身体(直径32厘米)圆柱形CTDI PMMA幻影与10厘米铅笔电离室进行评估。成人和儿童患者的CT剂量从头部、胸部、腹部和骨盆的普通CT检查中收集。CT剂量指数(CTDIvol)、剂量长度积(DLP)和有效剂量(E)是本项目评估的主要CT剂量学参数。所有CT系统的CTDIvol结果均与专业机构报告的结果符合。4家医院CT头部检查成人DLP值第3四分位数范围为384.106 ~ 5031.92 mg .cm。成人CT胸部检查显示第三四分位DLP值在122.035 ~ 1423.06 mGy之间。腹部和骨盆检查显示范围为258.446-1701.135 mg .cm。医院的DD3、AA13和ANM14均在阿联酋最初调整的当地剂量参考水平(drl)之内,与欧洲指南相当,而医院的TA1和TA2则更高。除了在TA1和TA2进行的CT检查外,几乎所有检查类型的CT有效剂量都在ICRP等国际组织提到的水平内(2007年第102号报告)。进一步的工作是减少病人在头部、胸部、腹部和骨盆的普通CT检查中的辐射剂量。阿联酋其他医院的成人和儿科患者数据收集和CT剂量分析正在进行中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信