{"title":"A comparative study on different control techniques on bridgeless interleaved AC-DC converter for power factor correction","authors":"V. Kannan, P. Balakrishnan, T. Isha","doi":"10.1109/ICCPCT.2016.7530118","DOIUrl":null,"url":null,"abstract":"Most of the AC-DC systems include an AC DC converter for power factor correction followed by an isolated DC-DC converter. AC-DC converters will introduce harmonics to the input current waveform as it contains nonlinear elements, so a suitable control technique is required to smoothen the input current to reduce harmonics. For high power applications, Bridgeless interleaved (BLIL) AC-DC converter is a preferred choice. In this paper, a comparison of different control techniques that can be used for power factor correction is presented. The comparison is done with THD of supply current, supply distortion factor and supply power factor. Simulation of a BLIL converter is carried out in MATLAB/SIMULINK environment using various control techniques and the results are presented.","PeriodicalId":431894,"journal":{"name":"2016 International Conference on Circuit, Power and Computing Technologies (ICCPCT)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Circuit, Power and Computing Technologies (ICCPCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCPCT.2016.7530118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Most of the AC-DC systems include an AC DC converter for power factor correction followed by an isolated DC-DC converter. AC-DC converters will introduce harmonics to the input current waveform as it contains nonlinear elements, so a suitable control technique is required to smoothen the input current to reduce harmonics. For high power applications, Bridgeless interleaved (BLIL) AC-DC converter is a preferred choice. In this paper, a comparison of different control techniques that can be used for power factor correction is presented. The comparison is done with THD of supply current, supply distortion factor and supply power factor. Simulation of a BLIL converter is carried out in MATLAB/SIMULINK environment using various control techniques and the results are presented.
功率因数校正的无桥交错交直流变换器不同控制技术的比较研究
大多数AC-DC系统包括一个用于功率因数校正的AC-DC转换器,然后是一个隔离的DC-DC转换器。交直流变换器的输入电流波形中含有非线性元素,会产生谐波,因此需要一种合适的控制技术来平滑输入电流以减少谐波。对于大功率应用,无桥交错(bll) AC-DC转换器是首选。本文对可用于功率因数校正的不同控制技术进行了比较。并与电源电流、电源畸变因数和电源功率因数的THD进行了比较。在MATLAB/SIMULINK环境下,采用多种控制技术对bll变换器进行了仿真,并给出了仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信