{"title":"Fitness-for-Service Assessment of Externally Corroded Convection Coil Tube","authors":"G. Zyl, Abdullatif Al-Salmi","doi":"10.1115/pvp2019-93829","DOIUrl":null,"url":null,"abstract":"\n During inspection of a heating coil in the convection section of a steam reformer, significant thickness loss due to external corrosion was discovered in a large number of tubes.\n In order to optimize the scope of repairs and ensure further safe operation, a level 3 fitness-for-service and remaining life analysis were performed in accordance with API-579.\n This paper will describe the fitness-for-service assessment that was performed, first using an idealized geometry, and thereafter using the actual corroded geometry of a removed tube. The procedure used to estimate the remaining life of the damaged coil will also be presented.","PeriodicalId":150804,"journal":{"name":"Volume 3: Design and Analysis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Design and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/pvp2019-93829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
During inspection of a heating coil in the convection section of a steam reformer, significant thickness loss due to external corrosion was discovered in a large number of tubes.
In order to optimize the scope of repairs and ensure further safe operation, a level 3 fitness-for-service and remaining life analysis were performed in accordance with API-579.
This paper will describe the fitness-for-service assessment that was performed, first using an idealized geometry, and thereafter using the actual corroded geometry of a removed tube. The procedure used to estimate the remaining life of the damaged coil will also be presented.